2.2 INSTALLATION DIAGRAMS
Input
Input
Cam 16
Cam 1
Output
Output
Spot Spot
Monitor
Main
Monitor
Main

RS-485

PSU
12 VDC
2A

RS-232

HEGS5000 System Controller

VCR

KX1610CN Multiplexe

r

2 - RX (data in)
5 - Ground
2 - RX (data in)
5 - Ground
RS-232
RS-232
+12VDC
GND
RS-232 (TX)RS-232 (RX)
RS-485 (D+)
RS-485 (D-)
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
GND
GND
RX (Data In)
RX (Data In)
DB9-Female
DB9-Male
+12VDC
GND
RS-232 (RX) RS-232 (TX)
RS-485 (D+)
RS-485 (D-)
Part #849193-0089
+-
GND
R232 TXS

Figure 1: Installing Honeywell Multiplexer, VCR, and Domes

Rev. 1.01 4 900.0800

19-Jun-06