5.2.5 Programming a VectorScan, Continued
13. Press Enter () when finished adding PreShots. The following commands are
displayed on the bottom of the monitor.
VectorScan Commands
E= Edit Press + or – key until E is displayed on LCD and press
Char Select. Reposition the PTZ and/or change the
lens settings, then repeat steps 6 and 7.
D = Delete Press + or – key until D is displayed on LCD and press
Char Select. The PreShot # entered in step 6 is
deleted.
S = Save Press + or – key until S is displayed on LCD and press
Char Select. The current PTZ and lens (focus and iris)
settings are saved for the PreShot # entered in step 6.
14. Press + or – until the character (E, D, or S) for the desired action is displayed on
the controller LCD and then press Character Select (
A
BC
).
15. Program another VectorScan or press Clear/Manual () to exit the PreShot
Programming menu.
5.2.6 Run VectorScan
To run a programmed VectorScan continuously:
1. Enter the VectorScan # (0-9) using the numeric keys.
2. Press the VectorScan ( ) key.
The VectorScan runs continuously until the KD6/HD6 receives another command.
To run a programmed VectorScan one time through the programmed PreShots:
1. Press the Dome Menu (
1. ___
3. ___
) key.
2. Press + or – until VectorScan Menu is displayed and press Enter ().
3. Press + or – until Run Once is displayed on the LCD and press Enter ().
3. Enter the VectorScan # (0-9) using the numeric keys.
4. Press Enter ().
The dome goes to each programmed PreShot at the velocity programmed and for the
dwell time specified and then stops.
Rev. 1.01 31 900.0800
19-Jun-06