To locate Lighting Instructions:

GSA Gas-Fired Steam Boilers – User’s Information Manual

To locate Lighting Instructions:

Find your boiler model number on boiler nameplate (begins with GSA). Read the valve manufacturer’s model and name on the boiler gas valve. Locate the correct “Lighting Instruction” using the table below. Use only the Instructions applying to your boiler model and gas valve. If you are in doubt which to use, please contact your boiler installer/ technician for assistance.

GSA standing pilot

Boiler models

Page

With gas valve:

 

 

 

 

 

Honeywell VR8200 or VR8300

GSA-075 through GSA-250

4

 

 

 

Robertshaw 7200

GSA-075 through GSA-175

5

 

 

 

Maintain your boiler using this schedule:

Service technician

(covered in Boiler Manual — for use only by a qualified service technician)

 

Inspect:

 

 

• Reported problems

 

 

Boiler area

 

 

Air openings

 

 

• Flue gas vent system

 

 

Pilot and main burner flames

UP

 

Piping

 

Boiler heating surfaces

 

 

START-

 

• Burners and base

Service:

 

ANNNUAL

 

• Gauge glass

Start-up:

 

 

 

Perform start-up per manual

 

Check/test:

 

 

Gas piping

 

 

Boiler waterline

 

 

Limit controls and cutoffs

 

 

Boiler relief valve

 

Review:

 

 

• Review with owner

 

 

 

 

 

Owner maintenance

 

(see pages 6 – 8 for instructions)

 

 

Daily

• Check boiler area

 

• Check boiler pressure gauge

 

• Check air openings

Monthly

• Check boiler and system piping

Check venting system

Check/operate boiler relief valve

Check pilot and main burner flames

Periodically • Test low water cutoff

End of season • Shut down procedure

Part Number 550-110-739/0703