34-ST-03-57 Page 24

TABLE III - OPTIONS (continued)

 

STR9xx

 

 

 

 

 

 

 

 

3D

 

4G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approval

Approval Type

Location or Classification

Selection

 

 

 

 

 

Body

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No hazardous location approvals

 

9X



 

 

 

Explosion Proof

Class I, Div. 1, Groups A,B,C,D

 

 

 

 

 

 

 

Factory

Dust Ignition Proof

Class II, III Div. 1, Groups E,F,G

 

 

 

 

 

 

 

Non-Incendive

Class I, Div. 2, Groups A,B,C,D

1C

 

 

 

Mutual

 

 

 

Intrinsically Safe

Class I, II, III, Div. 1, Groups

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A,B,C,D,E,F,G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explosion Proof

Class I, Div. 1, Groups B,C,D

 

 

 

 

 

 

 

CSA

Dust Ignition Proof

Class II, III, Div. 1, Groups E,F,G

2J

 

 

 

Intrinsically Safe

Class I, II, III, Div. 1, Groups

 

 

 

 

 

 

 

 

 

 

 

 

A,B,C,D,E,F,G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SA

Intrinsically Safe

Ex ia IIC T4

4G

 

 

 

(Australia)

Non-Sparking

Ex n IIC T6 (T4 with SM option)

 

b

 

 

 

 

 

 

Intrinsically Safe,

EEx ia IIC T4, T5,T6

3S

 

 

 

 

Zone 0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

Flameproof, Zone 1

EEx d IIC T5, T6,

3D

 

 

 

 

Enclosure IP 66/67

 

 

 

 

 

 

 

 

 

 

 

 

ATEX*

Non-Sparking,

EEx nA, IIC T6

3N

 

 

 

Zone 2

(Honeywell). Enclosure IP 66/67

 

 

 

 

 

 

 

 

 

 

 

 

Multiple Marking**

Ex II 1 G EEx ia IIC T4, T5, T6

 

 

 

 

 

 

 

 

Int. Safe, Zone 0/1, or

Ex II 2 G EEx d IIC T5, T6

3H

 

 

 

 

Flameproof, Zone 1, or

Ex II 3 G EEx nA, IIC T6 (Honeywell)

 

 

 

 

 

 

 

 

 

 

 

 

Non-Sparking, Zone 2

Enclosure IP 66/67

 

 

 

 

 

 

 

INMETRO

Flameproof, Zone 1

Ex d IIC T5

6D

 

 

 

(Brazil)

 

 

 

 

 

 

 

 

 

*See ATEX installation requirements in the ST 3000 User's Manual

 

 

 

 

 

 

 

**The user must determine the type of protection required for installation of the equipment. The user shall then check the box [

]

 

 

adjacent to the type of protection used on the equipment certification nameplate. Once a type of protection has been checked on

 

 

the nameplate, subsequently the equipment shall not be reinstalled using any of the other certification types.

 

 

 

 

 

TABLE IV

Factory Identification

XXXX

Page 24
Image 24