Honeywell Meters, STT250 Dimensions, Stainless Steel Direct Head Mount Housing, B-B section

Models: STT250

1 6
Download 6 pages 10.49 Kb
Page 3
Image 3
316 Stainless Steel Direct Head Mount Housing

316 Stainless Steel Direct Head Mount Housing

Suitable for corrosive/ salt spray environments and for general purpose or Intrinsically Safe applications.

Dimensions shown in Fig. 4. Housing entry length = 40 mm Material : 316SS

Sensor entry : 1/2”NPT

Cable/ conduit entry : 1/2”NPT or M20x1.5

Paint cover : none.

Weight : 1.6kg (3.5 lb) Enclosure classification IP65

Order as STT250 Table II selection S _ _. Flame-Proof version available.

33

1/2"NPT orM20

 

2 x M4

100

40

 

80

1/2" NPT

B-B section

A-A section

Figure 4

Meters

Honeywell’s Series STT250 Temperature Transmitters can be supplied with local or remote indication. An Analogue or Smart meter can be mounted integral to the transmitter inside the field mount housing. Order an integral meter as part of the model number; Table II _ _ M and _ _ S, respectively. Order a remote meter as model RMA300.

The analogue meter is a 4-20mA moving coil type and displays the temperature in 0 to 100% span.

The Smart meter accepts 4-20mA or DE protocol and displays temperature on a LCD in engineering units or 0 to

100% span. The Smart meter displays temperature in 0 to 100% span with the STT25H HART unit. Refer to 34-ST- 25-08D for more details.

The remote digital meter reads DE protocol and displays temperature on a LCD in 0 to 100% span. Refer to 34-ST-25- 07A for details.

STT250 Dimensions

Aluminium Pipe or Wall (Field) Mount Housing

Suitable for pipe or wall mounting remote from the temperature sensor, for direct sensor head mounting (in North America), for local indication and for Explosion-Proof (FM/ CSA and Cenelec), Intrinsically Safe or general purpose applications.

Dimensions shown in Fig. 5 and 6. Material : Low copper Aluminium alloy Cable/ Conduit entries : 1/2”NPT.

Paint cover : Beige polyester/ epoxy hybrid or beige epoxy painted.

Weight : 1.1kg (2.4 lb)

Enclosure classification : IP65. Conforms to the applicable requirements of NEMA 7and 9 for FM/ CSA Explosion-Proof applications.

Order as STT250 Table II selection E _ _ or X _ _, respectively.

316 Stainless Steel Pipe or Wall (Field) Mount Housing

Suitable for corrosive/ salt spray environments and for pipe or wall mounting remote from the temperature sensor, for direct sensor head mounting (in North America), for local indication and for Explosion-Proof (FM/ CSA and Cenelec), Intrinsically Safe or general purpose applications.

Dimensions shown in Fig. 5 and 6. Material : 316SS

Cable/ Conduit entries : 1/2”NPT. 3/4” NPT or M20 available via an adaptor.

Paint cover : none.

Weight : 3.2 kg (6.9 lb)

Enclosure classification : IP65

Order as STT250 Table II selection T _ _.

EN0I-6032

3

Page 3
Image 3