T7200D,E, T7300D,E,F AND Q7300 SERIES 2000 PROGRAMMABLE COMMERCIAL THERMOSTATS AND SUBBASES
63-4355418
Setting Program Temperature Setpoints

NOTE: The setpoint temperature range is 40°F to 90°F

(7°C to 31°C) for heating and 45°F to 99°F

(9°C to 37°C) for cooling.

1. Press Occupied Temp.

2. Press increaseor decrease until the desired

temperature is displayed.

3. Press Heat/Cool Settings to change between heat and

cool settings.

4. Press increaseor decrease until the desired

temperature is displayed.

5. Press Unoccupied Temp.

6. Press increaseor decrease until the desired

temperature is displayed.

7. Press Heat/Cool Settings to change between heat and

cool settings.

8. Press increaseor decrease until the desired

temperature is displayed.

9. Press Run Program.

Clearing Program Start Times

1. Press Occupied Start Time or Unoccupied Start Time

until the start time to be cleared is displayed.

2. Press Day until the desired day is displayed.

3. Press Clear Start Time.

4. Repeat steps 1 through 3 for all the start times to

be cleared.

5. Press Run Program.

Temporary Occupied Override

Setting Temperature Offset for Temporary Override

1. Press Occupied Temp.

2. Press Temporary Occupied.

M4970B
Heat
Setting
Occupied
Set Program
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Occupied
Temp Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
M4971B
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings Heat
Setting
Occupied
Set Program
Cool
Occupied
Setting
M4972A
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
Heat/Cool
Settings
Set Program
Cool
Setting
Occupied
M4973B
Set Program
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
Heat
Setting
UnOccupied
M4974B
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Unoccupied
Temp Heat/Cool
Settings
Set Program
Heat
Setting
UnOccupied
M4975B
Set Program
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
Un Cool
Setting
Occupied
M4976B
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
Heat/Cool
Settings
Set Program
Un Cool
Setting
Occupied
M4977B
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
Set Program
M4954A
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
Auto
System Fan
Mon
Room
AM
Occupied1
Heat
Run
Program
AM
Mon
Occupied1
Set Program
StartTime
M4955A
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
Occupied
Start Time
AM
Occupied1
Set Program
StartTime
M4978A
Mon
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
Day
Occupied1
Set Program
StartTime
M4979B
Mon
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
Clear
Start Time
M4954A
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
Auto
System Fan
Mon
Room
AM
Occupied1
Heat
Run
Program
M10231
Heat
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Occupied
Temp Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings
Wed
Occupied
Setting
M4980A
Set Program Set Temperature Change
Time/Temp
Occupied
Temp
Unoccupied
Start Time Day
System Fan
Copy
Occupied
Start Time
Run
Program
Temporary
Occupied
Temporary
Occupied
Continous
Unoccupied
Set Current
Day/Time Clear
Start Time
Unoccupied
Temp
Heat/Cool
Settings