Honeywell TC682EL, TS33C specifications Main Unit, Clock, Remote Sensor, Power, Dimensions

Models: TC682EL TS33C

1 6
Download 6 pages 47.2 Kb
Page 5
Image 5
Main Unit

BACKLIGHT

 

 

 

SPECIFICATIONS

 

The backlight feature is enabled only after the time is set.

Main Unit

 

To activate the backlight press the SNOOZE/LIGHT button

Indoor Temperature

: -5.0°C to +50.0°C/

once, and both – clock and weather station displays - will

Proposed operating range

light up for five seconds.

 

 

Temperature resolution

23.0°F to 122.0°F

PRECAUTIONS

 

 

: 0.1°C/0.2°F

 

 

Indoor Humidity

: 25%RH to 90%RH

• This product is engineered to give you years of satisfactory

Proposed operating range

service if handled carefully. Here are a few precautions:

Humidity resolution

: 1%

Do not immerse the units in water.

 

 

Comfort level indicators – COMFORT, WET and DRY

Do not clean the units with abrasive or corrosive

User-selectable (°F or °C) temperature display

 

 

materials. They may scratch the plastic parts and corrode

Weather Forecast in five large

: Sunny, Partly Cloudy,

the electronic circuits.

 

 

graphic icons

Do not subject the product to excessive force, shock, dust,

Remote channels auto-scan feature

Cloudy,RainyandSnowy

 

 

temperature, or humidity, which may result in malfunctions,

: 3 (one included)

shorter lifespan, damaged batteries, and damaged parts.

Maximum number of remote sensors

Do not tamper with the units internal components. Doing

Readings update interval

: every 45 seconds

 

 

so will invalidate the warranty and may cause damage.

EL backlight for the weather station ; Bulb backlight for

These units contain no user-serviceable parts.

analog clock

 

Use only fresh batteries. Do not mix new and old

Low battery indicators – for each remote channel and main unit

batteries.

 

 

 

Clock

 

Read the user's manual thoroughly before operating the

Precise Quartz Time

 

 

 

units.

 

 

 

Crescendo 2 minutes alarm with 4 minutes snooze

TROUBLESHOOTING

 

 

Remote Sensor

 

 

 

Remote Temperature

 

Check here before contacting customer service.

Proposed operating range

: -20.0°C to + 70.0°C/

 

 

 

 

 

 

with alkaline batteries

 

 

Issue

Symptom

Solution

 

 

-4.0°F to + 158°F

 

 

Temperature or

Displays "LL" or

Temperature or

 

Proposed operating range

 

 

 

 

 

 

Humidity

"HH"

humidity out of range

 

: -38.8°C to + 70.0°C/

 

 

 

with lithium batteries

 

 

Remote sensor

Cannot locate remote

Check batteries

 

 

-38.0°F to +158°F

 

 

 

sensor

Check location

 

Temperature resolution

: 0.1°C/0.2°F

 

 

 

Cannot change the

Press "RESET" after

 

RF Transmission Frequency

: 433 MHz

 

 

 

channel

setting the channel

 

RF range: Maximum 200 feet (60 meters)

 

 

 

Cannot change the ºC

Press "RESET" after

 

Temperature & humidity transmission cycle : approximately

 

 

 

to ºF and back

setting ºC/ºF

 

 

45 seconds

 

 

 

Data does not match

Initiate manual sensor

 

Low battery indicator

 

 

 

 

 

 

 

 

data on the main unit

search

 

Wall-mount of Table stand

 

 

 

 

17

 

 

18

 

 

 

 

 

 

 

 

 

Power

: 2 AA size (UM-3) 1.5V

DECLARATION OF CONFORMITY

Main unit

We

Remote Sensor

batteries (not included)

Manufacturer: Hideki Electronics Ltd.

: 2 AA size (UM-3) 1.5V

Address: Unit 2304-06, 23/F Riley House, 88 Lei Muk Road,

Dimensions

batteries (not included)

Kwai Chung, New Territories, Hong Kong

: 3.32(L) x 6.97(H) x

declare that the product

Main unit

Product No.: TC682EL

Remote sensor

1.49(D) inches

Product Name: Honeywell Wireless Digital Weather Station

: 2.37(L) x 4(H) x

with Analog Clock is in conformity with Part 15 of the FCC

 

1(D) inch

Rules. Operation is subject to the following two conditions:

FCC STATEMENT

 

This device may not cause harmful interference.

 

This device must accept any interference received, including

This device complies with Part 15 of the FCC Rules.

interference that may cause undesired operation.

Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and

The information above is not to be used as a contact for

(2) This device must accept any interference received,

support or sales.

including interference that may cause undesired operation.

Warning: Changes or modification to this unit not expressly

 

approved by the party responsible for compliance could

 

void the user’s authority to operate the equipment.

 

NOTE: This equipment had been tested and found to comply

 

with the limits for a Class B Digital device, pursuant to Part

 

15 of the FCC Rules. These limits are designed to provide

 

reasonable protection against harmful interference in a

 

residential installation. This equipment, installed and used

 

in accordance with the instructions, may cause harmful

 

interference to radio communications.

 

There is no guarantee that interference will not occur in a

 

particular installation. If this equipment does cause harmful

 

interference to radio or television reception, which can be

 

determined by turning the equipment off and on, the user is

 

encouraged to improve or correct turning the interference by

 

one or more of the following measures:

 

• Reorient or relocate the receiving antenna

 

• Increase the separation between the equipment and receiver.

 

• Connect the equipment to an outlet on a circuit different

 

from that to which the receiver is connected.

 

• Consult the dealer or an experienced radio / TV technician

 

for help.

19

20

 

 

 

 

Page 5
Image 5
Honeywell TC682EL, TS33C specifications Main Unit, Clock, Remote Sensor, Power, Dimensions