W8600F Air Cleaner Monitor

W8600F Air Cleaner Monitor

INSTALLATION INSTRUCTIONS

APPLICATION

The W8600F Air Cleaner Monitor is an option available for use with the F50F and F52F Honeywell Electronic Air Cleaners (EAC). The series two F50F and F52F require a solid state power supply that is compatible with the W8600F driver board. Any series one F50E, F or F52F can be upgraded to use the W8600F when the power supply is replaced and the driver board (included in W8600F kit) is installed.

The W8600F function indicator panel has four liquid crystal display (LCD) arrowheads that point to ON, BATTERY, SERVICE or FAULT. See Fig. 1. The arrowheads darken to indicate the existing EAC condition. See Table 1.

LCD

ON

BATTERY

SERVICE

 

FAULT

 

Air Cleaner Monitor

FUNCTION

INDICATOR

 

PANEL

INSTALLATION

When Installing this Product..

1.Read these instructions carefully. Failure to follow the instructions could damage the product or cause a hazardous condition.

2.Check the ratings given in the instructions and on the product to make sure the product is suitable for your application

3.Installer must be a trained, experienced service technician.

4.After completing the installation, use these instruc- tions to check out the product operation.

Location

The styling of the W8600F is designed to blend with the latest T8600 family of Honeywell Chronotherm¨ IV Deluxe Programmable Thermostats. A special mounting template is included for mounting next to the T8600. The W8600F can also be mounted at any other convenient location in the living area or equipment room. See Fig. 2.

NOTE: The W8600F shares no common electrical con- nections with the thermostat.

RESET BUTTON

M11965

Fig. 1. W8600F Air Cleaner Monitor features.

Table 1. Description of W8600F Function Indicator

Panel.

 

 

Indicators

Condition

 

 

ON

EAC is powered and system blower is

 

running.

 

 

BATTERY

Battery that maintains W8600F

 

memory is low and needs to be

 

replaced.

 

 

SERVICE

EAC prefilter and cells need to be

 

washeda.

FAULT

•Shorting of collector plates.

 

•Continuous ionizer or collector plate

 

arcing.

 

•Power supply failure.

 

•Excessive current.

 

•Major reduction in high voltage.

 

•EAC prefilter and cells are past

 

SERVICE level of dirt and need to be

 

washed immediately.

 

Call a service technician.

 

 

aThe reset button is located on the bottom of W8600F. After the prefilters and cells are cleaned and reinstalled, press this button to turn off the SERVICE indicator and reset the wash frequency timer.