Select Wash Frequency

W8600F AIR CLEANER MONITOR

Select Wash Frequency

Use the W8600F DIP switches to program the time between SERVICE indications. Be sure to select the setting according to the conditions of the home. Factors to consider include the duty cycle of the EAC, the number of people and pets, and activities such as woodworking and other crafts that are being done in the home.

Refer to Table 2 to select the wash frequency. Set the W8600F DIP switches to match the selection. See Fig. 4. The time listed represents actual run time of the EAC, not calendar days.

Table 2. Wash Frequency Options.

 

 

 

 

DIP Switch Settings

Wash Frequency

 

 

 

 

1

2

3

Days (Run Time)

 

 

 

 

Off

Off

Off

10

 

 

 

 

On

Off

Off

20

 

 

 

 

Off

On

Off

30

 

 

 

 

On

On

Off

40

 

 

 

 

Off

Off

On

50

 

 

 

 

On

Off

On

70

 

 

 

 

Off

On

On

100

 

 

 

 

On

On

On

180

 

 

 

 

BACK OF W8600F

BATTERY

IN HOLDER

DIP SWITCHES

3.Check that the battery is correctly installed in the W8600F battery holder.

4.Snap the W8600F onto the base.

5.Turn off the power for the EAC.

Wiring WARNING

Electric Shock Hazard.

Can cause electrical shock or equipment damage.

Disconnect EAC power and open the access door before opening power supply box cover.

6.Open the power supply box cover.

7.Remove the plug from the side of the power supply box (plug can be a metal knockout or a blank termi- nal strip).

8.Install the terminal block/cable assembly supplied with W8600F kit.

9.Plug the connector on the end of the cable assem- bly into the J2 terminal on the driver board (included with W8600F kit). See Fig. 5.

POWER SUPPLY

BOX COVER Manual background

AIR

SYSTEM

DRIVER

J2 BOARD

TERMINAL

STRIPJ1Manual background

MOUNTING

SCREW

POWER

SUPPLY

UP

1 2 3

1

3

4

WIRING TERMINALS (3)

RESET BUTTON

Manual background POWER SUPPLY BOX

M11970

Fig. 5. Installing the driver board on the EAC.

10.Plug the driver board assembly into the J1 power supply connector.

M11969A

Fig. 4. Back of W8600F.

Wiring

1.Run a 3 -conductor thermostat cable (up to

18 gauge) from the W8600F to the terminal strip on the air cleaner.

IMPORTANT

Connect cable to W8600F before attaching to the air cleaner terminals to minimize the risk of damage due to static electricity.

2.Connect the wires to terminals E1, E3 and E4 on the W8600F. See Fig. 4.

NOTE: This W8600F kit is configured to operate with a power supply that is controlled by an airflow switch (AFS). If your application does not have an AFS, place the black shorting bar (found in the bag assembly) on power supply connector J3, pins 1 and 2, as shown in Fig. 6.

Manual background SHORTING BAR

J3

4

3

2

1

M20890

Fig. 6. Placing shorting bar on power supply for

applications without AFS.

11.Replace the power supply box cover.

3