Image 3
1. Assembly

1. Assembly

Operate cleaning system only at voltage specified on power unit.

This system is intended for household use.

Grounding

Instructions

This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electrical current to reduce the risk of electric shock. This appliance is equipped with a cord hav- ing an equipment-grounding conductor

(A)and grounding plug (B). The plug must be plugged into an appropriate outlet (C) that is properly installed and grounded in accordance with all local codes and ordinances.

DANGER-

Improper connection of the equipment- grounding conductor can result in the risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. This appliance is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in Fig. 1-1.

A Temporary adapter (D) may be used to connect this plug to a 2-pole recepta- cle (E) if a properly grounded outlet is not available. The Temporary adapter should be used only until a properly grounded outlet (C) can be installed by a qualified electrician. The green col- ored rigid ear (F), lug, or the like extend- ing from the adapter must be connected to a permanent ground such as a prop- erly grounded outlet box cover. Whenever the adapter is used, it must be held in place by a metal screw (G).

1-1

B

A C

1-2

D

F

G

E

NOTE: In Canada, the use of a tempo- rary adapter is Not Permitted by the Canadian Electrical Code.

Description

 

1-3

1

 

6

2

 

 

15

 

13

5

11

 

9

LR37447 C UL E119989

CANAVAC SYSTEMS INC

ONTARIO, CANADA

120 V

60 HZ

Serial No.

No. Desé rie

Mount at least 12 in. from ceiling.

Connect to individual brance circuit.

WARNING: To reduce the risk of electric shock do not use outdoors or on wet surfaces.

Assurer un dé gagement d'au moids 12 po. entre les plafond selon les cas.

Brancher a une derivation distincte

AVERTISSEMENT:Pour reduire les risgues de choc electrique ne pas utiliser a l'exterieur et ne pas aspiere de matieres humides.

10

3

7

6

Grounding8

 

14

12

 

4

16

1.

Motor module

9. Power cord

2.

Motor exhaust port

10.

Data label

3.

Mounting bar

11. Exhaust muffler

4.

Dust container (contains

12.

Hose inlet port (S5626 &

 

Items 11, 13, 14, 15 & 16)

 

S5636 only)

5.

Filtration body

13.

Sweep 90° fitting

6.

ON-OFF switch

14.

Hose inlet valve

7.

Over load protector

 

w/24 volt connection)

8.

Low voltage receptacle

15.

90° elbow

 

(24 volt)

16.

Mounting bracket

3