Hoover Deep Cleaner Steam Vacuum manual Storage, Lubrication, Problem Machine won’t run

Models: Deep Cleaner Steam Vacuum

1 17
Download 17 pages 34.52 Kb
Page 16
Image 16
Storage

Storage

Before storing:

Empty clean water tank and let air dry. Replace on deep cleaner.

Unused detergent can be stored in the detergent container.

Empty recovery tank, rinse tank and lid thoroughly with clean water and let air dry.

Allow brushes and underside of deep cleaner to air dry thoroughly before storing deep cleaner on a carpeted or wood surface.

Do not store deep cleaner with a full clean water tank in place.

Lubrication

The motor is equipped with bearings which contain sufficient lubrication for the life of the motor. The addition of lubricant could cause damage. Do not add lubricant to motor bearings.

5Possible. Ifcauseyou have a Possible solution

problem• Rec very tank full/automatic

If a minor problem occurs, it usually can be solved quite easily when the cause is found by using the check list below.

Problem: Machine won’t run

Possible cause

Possible solution

Not firmly plugged in

Plug unit in firmly

No voltage in wall plug

Check fuse or breaker

Blown fuse/tripped breaker

Replace fuse/reset breaker

Problem: Low solution pick-up

Possible cause

Possible solution

Recovery tank full/automatic shut off engaged

Remove and empty recovery tank

Blockage in tool on end of hose

Remove tool and clear blockage

Recovery tank lid not on correctly

Make sure lid is on securely

Water tank empty, but detergent remains

Fill water tank

Problem: Clean water won’t

dispense

Possible cause

Possible solution

Clean water tank not firmly in place

Make sure tank is securely locked in position

Clean water tank or detergent container empty

Refill container according to instruc- tions for surface being cleaned

Recovery tank lid not on correctly

Make sure lid is firmly in place

Problem: Detergent won’t

dispense

Possible cause

Possible solution

Valve cap clogged

Remove and clean valve cap (see fol- lowing instructions)

1. Remove clean water tank.

5-1

A

A

2.Turn valve cap (A) counterclockwise and remove.

Soak valve cap in warm water for at least 15 minutes. Wipe cap dry.

5-2

C

B

3.Align slots (B) on cap with tabs (C) in opening.

Turn cap clockwise to tighten.

Problem: Brushes won’t rotate during

floor cleaning

Possible cause

Possible solution

Dirty filter screen on bottom of unit

Clean screen as shown in Fig. 3-2

Setting selector on OFF

Move setting selector to ON

16

Page 16
Image 16
Hoover Deep Cleaner Steam Vacuum manual Storage, Lubrication, Problem Machine won’t run, Problem Low solution pick-up