Pivot off bottom plate making sure to unhook center tab on inside edge of nozzle (opposite edge with screws).
|
C |
If belt (C) is stretched, remove it from the motor pulley.
Remove agitator and belt from nozzle.
|
Put new belt on agitator.
Position agitator in nozzle orienting agi- tator end caps with slots on both sides of nozzle. End cap with side projections (Fig.
The agitator end caps may fall off during belt replacement. For correct orientation of end caps onto agitator, see “How to replace Agitator Brush.”
|
E |
D |
F |
The belt should line up with tab (F) on inside of nozzle.
|
Attach belt to motor pulley.
Replace bottom plate by first hooking it to center tab on inside of nozzle.
Reposition screws and front cover.
|
G |
Make sure “bridge” (G) across bottom plate opening covers belt. If belt is not covered, agitator is not correctly orient- ed in nozzle.
|
Agitator brush
Disconnect cleaner from electrical outlet.
To check condition of agitator brushes, move the edge of a card across agitator opening. Rotate agitator by hand. If brushes do not touch edge of card, replace the agitator.
6
What to buy
When replacing the agitator, ask for HOOVER agitator complete with end caps, part No. 59139205.
How to replace
Disconnect cleaner from electrical outlet.
Remove bottom plate, agitator and belt following directions for “How to replace belt.”
Discard old agitator and end caps.