Edge groomer replacement

When to replace

The edge groomers, located on both sides of the nozzle, should be re p l a c e d when they no longer extend past the sur- face of the bottom plate.

What to buy

When purchasing edge groomers, ask for Hoover p a rt n o . 3 9 5 1 1 0 0 4 .

How to replace

Disconnect cleaner from electrical outlet.

1.Remove hood and b rush ro l l cover as shown in Figs. 3-9 to 3-12.

3 - 20

H

G

2. Pull off both old edge groomers (G).

3.Push each new groomer onto the 3 tabs (H), starting with one of the end tabs. Then push the groomer onto the middle and remaining end tab.

4.Replace brush roll cover and hood as shown in Figs. 3-16 and 3-17.

Powered hand tool Agitator brush roll replacement

When agitator brush roll brushes are worn, the brush roll should be replaced. Ask for HOOVER part no. 48414088.

3 - 21A

How to replace

Disconnect cleaner from electrical outlet.

1.Remove tool from hose and turn it so bottom faces up. Press the latches on either side of tool and remove bottom plate (A).

3 - 22

3 - 23

3 - 24

 

 

 

D

B

C

CE

2.Unscrew the two Philips screws and remove belt guard (B).

3.Remove agitator including end plates

(C) and discard.

4.Inspect belt to ensure that it is in good condition. If belt is cracked, gouged or broken, replace it (see follow- ing section).

5.Insert brush roll through belt and position belt over gear teeth (D) on brush roll.

6.With curved ends down, slide end plates (C) of brush roll into slots (E) on tool.

3 - 25

 

3 - 26

 

 

 

B

A

7.Replace belt guard (B) making sure not to pinch brush bristles in guard. Turn agitator, making sure it rotates freely.

Replace and tighten screws.

8.To replace bottom plate (A), insert the four tabs on edge of bottom plate into slots on front of tool.

Pivot bottom plate down and snap

closed.

11

Page 11
Image 11
Hoover TurboPOWER WindTunnel Canister Cleaner with Powered Hand Tool owner manual Edge groomer replacement, 21A