Hoover WindTunnel Lubrication, Edge groomer replacement, Thermal protector, Belt replacement

Models: WindTunnel

1 14
Download 14 pages 11.93 Kb
Page 12
Image 12
Belt replacement

6.With curved ends down, slide end plates (C) of brush roll into slots (E) on tool.

7.Replace belt guard (B) making sure not to pinch brush bristles in guard. Turn agitator, making sure it rotates freely.

Replace and tighten screws.

8.To replace bottom plate (A), insert the four tabs on edge of bottom plate into slots on front of tool.

Pivot bottom plate down and snap closed.

Powered hand tool

Belt replacement

The powered hand tool belt is designed to last a long time and is not normally replaced. However, if the belt is crack- ed, gouged or broken, it should be replaced.

Replacing belt

When replacing belt, ask for HOOVER

part No. 38528037.

1.Remove bottom plate, belt guard and brush roll as described in Figs. 3-19 through 3-21.

4.With flat sides of turbine retainers (G) pointing down, slide retainers into grooves (H) in tool housing and snap into place.

5.Replace brush roll, belt guard, and bottom plate as described in Figs. 3-21 t h r o u g h 3 - 2 4 .

I

-

The belt can be seen through the top of the nozzle or by removing the bottom plate and belt guard (Figs. 3-19 and 3-20.

2.Grasp turbine (E) and pull firmly to remove.

3.Remove belt from turbine pulley (F). Replace with new belt.

Edge groomer replacement

When to replace

The edge groomers, located on both sides of the front of the cleaner, should be replaced when they no longer extend past the surface of the bottom plate.

What to buy

When purchasing edge groomers, ask for HOOVER part No. 39511004.

Replacing edge groomers

Disconnect cleaner from electrical outlet.

Warning - Brush roll can start sud- denly. Unplug cleaner when it is turned over.

Remove bottom plate as described in Fig. 3-9.

Lift off both old edge groomers and slide new edge groomers into position as shown.

Reposition bottom plate and secure with 4 Phillips head screws (Fig. 3-14).

Lubrication

The motor is equipped with bearings that contain sufficient lubrication for the life of the motor. The addition of lubricant could cause damage. Therefore, do not add lubricant to motor bearings. The agitator is equipped with two ball bearings that should be lubricated peri- odically by a Hoover Factory Service Center or an Authorized Hoover Warranty Service Dealer (Depot).

Thermal protector

An internal thermal protector has been designed into your cleaner to protect it from overheating.

When the thermal protector activates, the cleaner will stop running. If this happens, proceed as follows:

1.Turn the cleaner OFF and discon- nect it from the electrical outlet.

2.Check secondary and final filters for dirt accumulation.

3.Refer to “Clearing blockages” sec-

tion

4.When cleaner is unplugged and the motor cools for 30 minutes, the thermal protector automatically resets and cleaning may continue.

If the thermal protector continues to activate after following the above steps, your cleaner may need servicing (see ‘Service” section).