![](/images/new-backgrounds/1247279/24727935x1.webp)
(29) Microswitch [Location]
Senses the location of the flow switching valve. (30) Microswitch [Direction]
Senses the direction of the flow switching valve. (31) Flow Control Valve
Located between the water supply inlet and the electrolytic cell. Adjusts the rate of water supply.
(32) Electrolytic Cell
Electrolyzes diluted salt water to generate sanitizing water and cleaning water. (33) Salt Water Pump (Electromagnetic Pump)
Feeds a fixed amount of concentrated salt water (electrolyte) into the electrolytic cell.
(34) Thermistor
Senses the water temperature and automatically reduces the electrolytic current to prevent excessive available chlorine concentration in low temperature conditions.
[c] CONTROL BOX
35 |
37 |
42 |
|
43 | 36 |
44 |
|
46 |
|
45 |
|
47 |
|
| 17 |
40 |
41 |
39 |
38 |