5. FUNCTIONS AND OPERATION
[a] NORMAL MODE
The following menus are available in the normal mode. The display shows from 1 to 3 every time the display select button is pressed.
No. | Menu | Description | |
|
|
| |
1 | Cell run time (h) | Total electrolytic cell run time at present. | |
2 | Current (A) | Current flowing in electrolytic cell at present as measured by | |
current sensor. | |||
|
| ||
3 | Voltage (V) | Voltage provided on electrolytic cell at present as measured | |
by main control board. | |||
|
|
[b] SHORT MODE
Use this mode to change the polarity every 2 minutes.
1)While the power switch (ground fault interrupter) is off, hold down the flush button and set/reset button.
2)Turn on the power switch (ground fault interrupter).
3)After 5 seconds, release the flush button and set/reset button.
Note: The operation lamp flashes while the short mode is selected.
[c] ADJUSTMENT MODE
The following menus are available in the adjustment mode.
No. | Menu | Factory default | Adjustable range/increments | |
|
|
|
| |
A1 | Current (A) | Lo: 10, Std: 10, Hi: 10 | 5.0 to 18.0/0.1 | |
[wt=77°F(25°C)] | ||||
|
|
| ||
A2 | Voltage (V) | Lo: 12, Std: 12, Hi: 12 | 7.0 to 18.0/0.1 | |
A3 | Total flow rate (L/min) | Lo: 3.0, Std: 4.0, Hi: 6.0 | 1.5 to 8.0/0.1 | |
A4 | Combination | 1 | Main: 1, Sub: 2 | |
A5 | Portion control time (min) | 1 | 1 to 60/1 | |
A6 | Cleaning water dispensing | 30 | 15 to 120/5 | |
| time for hand washing (s) |
|
| |
A7 | Sanitizing water dispensing | 30 | 15 to 120/5 | |
time for hand washing (s) | ||||
| Cell run time/reversal time |
| Display present run time, then | |
A8 | N/A | hold down set/reset button | ||
reset | ||||
|
|
| (10s) to reset | |
A9 | Initial flash time (s) | Std | Std, 0 to 20/1 |
21