Hoshizaki ROX-20TB2-U Functions and Operation, Normal Mode, Short Mode, Adjustment Mode

Models: ROX-20TB2-U

1 31
Download 31 pages 27.22 Kb
Page 22
Image 22

5. FUNCTIONS AND OPERATION

[a] NORMAL MODE

The following menus are available in the normal mode. The display shows from 1 to 3 every time the display select button is pressed.

No.

Menu

Description

 

 

 

1

Cell run time (h)

Total electrolytic cell run time at present.

2

Current (A)

Current flowing in electrolytic cell at present as measured by

current sensor.

 

 

3

Voltage (V)

Voltage provided on electrolytic cell at present as measured

by main control board.

 

 

[b] SHORT MODE

Use this mode to change the polarity every 2 minutes.

1)While the power switch (ground fault interrupter) is off, hold down the flush button and set/reset button.

2)Turn on the power switch (ground fault interrupter).

3)After 5 seconds, release the flush button and set/reset button.

Note: The operation lamp flashes while the short mode is selected.

[c] ADJUSTMENT MODE

The following menus are available in the adjustment mode.

No.

Menu

Factory default

Adjustable range/increments

 

 

 

 

A1

Current (A)

Lo: 10, Std: 10, Hi: 10

5.0 to 18.0/0.1

[wt=77°F(25°C)]

 

 

 

A2

Voltage (V)

Lo: 12, Std: 12, Hi: 12

7.0 to 18.0/0.1

A3

Total flow rate (L/min)

Lo: 3.0, Std: 4.0, Hi: 6.0

1.5 to 8.0/0.1

A4

Combination

1

Main: 1, Sub: 2

A5

Portion control time (min)

1

1 to 60/1

A6

Cleaning water dispensing

30

15 to 120/5

 

time for hand washing (s)

 

 

A7

Sanitizing water dispensing

30

15 to 120/5

time for hand washing (s)

 

Cell run time/reversal time

 

Display present run time, then

A8

N/A

hold down set/reset button

reset

 

 

 

(10s) to reset

A9

Initial flash time (s)

Std

Std, 0 to 20/1

21

Page 22
Image 22
Hoshizaki ROX-20TB2-U service manual Functions and Operation, Normal Mode, Short Mode, Adjustment Mode