Installation

 

 

 

 

 

 

WARNING – THIS APPLIANCE MUST BE EARTHED.

 

 

 

 

 

 

Your cooker should have been checked to ensure that the

 

 

 

 

 

 

 

 

 

 

 

 

voltage corresponds with your supply voltage, this is stated

 

 

 

 

 

 

on the rating plate, which is situated on the rear panel.

 

 

 

 

 

 

The cooker must be connected by a competent

 

 

 

 

 

 

person eg. (NICEIC registered contractor) to suitable

 

 

 

 

 

 

double-pole control unit with a minimum rating of 32A

 

 

 

 

 

 

 

 

 

 

 

 

and a minimum contact clearance of 3mm, which should

 

 

 

 

 

 

be fitted adjacent to the cooker, in accordance with IEE

 

 

 

 

 

 

 

 

 

 

 

 

regulations.

 

 

 

 

 

 

 

 

 

The power supply cable should conform to B.S.6004 with a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

conductor size of 6mm2 minimum.

 

 

 

 

 

 

The control unit should be easily accessible in the event of

 

 

 

 

 

 

an emergency, but must be within 2 metres of and not

 

 

 

 

 

 

directly above an appliance.

 

 

 

 

 

 

This appliance conforms to EN 55014 regarding

 

 

 

 

 

 

suppression of radio and television interference.

 

 

 

 

 

 

Access to the mains terminals is gained by removing the

 

 

 

 

 

 

 

 

 

 

 

 

rear access cover.

 

 

 

 

 

 

 

 

 

 

 

 

The mains cable must pass through the cable clamp

 

 

 

 

 

 

adjacent to the terminal block. Sufficient cable should be

 

 

 

 

 

 

used to allow the cooker to be pulled out for servicing.

 

 

 

 

 

 

Ensure that the mains cable is routed away from any

 

 

 

 

 

 

brackets affixed to the rear panel and is not trapped to the

 

 

 

 

 

 

rear wall when pushing the cooker into position between

 

 

 

 

 

 

cabinets.

Siting the Cooker

 

 

 

The cooker is designed to fit between kitchen

 

 

 

 

 

 

cabinets spaced 500mm apart. The space either side need

 

 

 

 

 

 

only be sufficient to allow withdrawal of the cooker for

 

 

 

 

 

 

servicing. It can be used with cabinets one side or both

 

 

 

 

 

 

as well as in an angled corner setting. It can also be used

 

 

 

 

 

 

free standing.

This cooker is a Type X appliance, as such adjacent side walls which project above hob level, must not be nearer to the cooker than 150mm and should be protected by heat resistant material. Any overhanging surface or cooker hood should not be nearer than 650mm.

The height of the cooker can be adjusted by means of adjustable feet in the plinth (900mm - 915mm). Adjust the feet by tilting the cooker from the side. Then install the cooker into position.