connection required and position the connection

GB supports as shown in the following table and diagrams.

4.Position the wires in accordance with the information given in the following table and diagrams and connect the appliance by tightening all the screws for the springs as much as possible.

Voltage and

Electrical connections

Terminal board

mains frequency

 

 

 

400V 3-N ~

 

Three-phase 400

50/60 Hz

 

 

 

 

 

 

5.Secure the power supply cable by fastening the cable clamp screw, then put the cover back on.

Connecting the electricity supply cable to the mains

If the appliance is being connected directly to the electricity mains an omnipolar switch must be installed with a minimum opening of 3 mm between contacts.

!The installer must ensure that the correct electrical connection has been made and that it is fully compliant with safety regulations.

Before connecting the appliance to the power supply, make sure that:

Phase Phase

1

2

5

Phase

 

3

Three-phase 400

4

 

The appliance is earthed and the plug is

 

compliant with the law.

The socket can withstand the maximum power of

 

the appliance, which is indicated on the data

 

plate located on the appliance itself.

The voltage falls within the range of values

 

indicated on the data plate.

The socket is compatible with the plug of the

 

appliance. If the socket is incompatible with the

Earth

Neutral

U-bolt

 

 

connection support

plug, ask an authorised technician to replace it.

Do not use extension cords or multiple sockets.

!Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible.

!The cable must not be bent or compressed.

!The cable must be checked regularly and replaced by authorised technicians only.

!The manufacturer declines any liability should these safety measures not be observed.

!Do not remove or replace the power supply cable for any reason. Its removal or replacement will void the warranty and the CE marking. INDESIT does not assume liability for accidents or damage arising from replacement/removal of the original power supply cable. Replacement can only be accepted when carried out by personnel authorised by INDESIT and using an original spare part.