BURNER AND NOZZLE SPECIFICATIONS

Table 1

 

 

 

 

 

Liquid gas

 

 

Natural gas

 

 

 

 

 

 

 

 

 

 

 

 

Diameter

Thermal Power kW

 

By-pass

Nozzle

Flow *

Nozzle

Flow *

 

(mm)

(H.s.)*

 

1/100

1/100

 

g/h

1/100

l/h

BURNER

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal

Reduced

 

(mm)

(mm)

G30

 

G31

(mm)

G20

 

 

 

 

 

 

 

 

 

 

 

 

C. Rapid

100

3.00

0.7

 

40

86

218

 

214

116

286

 

 

 

 

 

 

 

 

 

 

 

 

B. Semi-rapid

75

1.65

0.4

 

30

64

120

 

118

96

157

 

 

 

 

 

 

 

 

 

 

 

 

A. Auxiliary

55

1.0

0.3

 

27

50

73

 

71

71

95

 

 

 

 

 

 

 

 

 

 

 

 

D. Triple Ring

130

3.25

1.3

 

57

91

236

 

232

124

309

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal (mbar)

 

 

28-30

 

37

 

20

Supply pressures

 

Minimum (mbar)

 

 

20

 

25

 

17

 

 

Maximum (mbar)

 

 

35

 

45

 

25

 

 

 

 

 

 

 

 

 

 

 

 

*At 15°C and 1013 mbar-dry gas Propane P.C.S. = 50.37 MJ/Kg

Butane

P.C.S. = 49.47 MJ/Kg

Natural

P.C.S. = 37.78 MJ/m3

This appliance conforms to the following European Eco- nomic Community directives:

-73/23/EEC of 19/02/73 (Low Voltage) and subsequent modifications;

-89/336/EEC of 03/05/89 (Electromagnetic Compatibility) and subsequent modifications;

-90/336/EEC of 29/06/90 (Gas) and subsequent modifi- cations;

-93/68/EEC of 22/07/93 and subsequent modifications.

Disposal of old electrical appliances

The European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE), requires that old household electrical appliances must not be disposed of in the normal unsorted municipal waste stream. Old appliances must be collected separately in order to optimise the recovery and recycling of the materials they contain and reduce the impact on human health and the environment. The crossed out “wheeled bin” symbol on the product reminds you of your obligation, that when you dispose of the appliance it must be separately collected.

Consumers may take their old appliance to public waste collection areas, other communal collection areas, or if national legislation allows return it to a retailer when purchasing a similar new product.

All major household appliance manufacturers are active in the creation of systems to manage the collection and disposal of old appliances.

OVEN SPECIFICATIONS

Inner Volume of the ELECTRIC Oven:

68 litres

Voltage and Frequency of Power Supply:

230V ~ 50Hz 2800W

16