Characteristic of the burners and nozzles

Characteristic of the burners and nozzles

Table 1

 

 

 

 

 

Liquid Gas

 

 

Natural Gas

City Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Diameter

Thermal power

By-Pass

Nozzle

 

Flow*

Nozzle

 

Flow*

Nozzle

 

Flow*

 

(mm)

kW (p.c.s.*)

1/100

1/100

 

g/h

1/100

 

l/h

1/100

 

l/h

(mm)

 

Nomin.

 

Ridot.

(mm)

(mm)

***

 

**

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fast (R)

90x90

3,00

 

0,70

39

86

218

 

214

116

 

286

285

 

680

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi Fast (S)

65x65

1,90

 

0,40

28

70

138

 

136

103

 

181

185

 

374

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary (A)

45x45

1,00

 

0,40

28

50

73

 

71

72

 

95

145

 

227

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply

Nominal (mbar)

 

 

28-30

 

37

20

 

 

8

Minimum (mbar)

 

 

20

 

25

17

 

 

6

Pressures

 

 

 

 

 

Maximum (mbar)

 

 

35

 

45

25

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*At 15°C and 1013 mbar-dry gas

**Propane P.C.S. = 50.37 MJ/kg.

***Butane P.C.S. = 49.47 MJ/kg. Natural P.C.S. = 37.78 MJ/m3