Hotpoint GP641X Setting the burners to minimum, Turn the tap to the low flame position, steady

Models: GP641X

1 16
Download 16 pages 11.29 Kb
Page 4
Image 4
• Setting the burners to minimum:

• Setting the burners to minimum:

GB

1. Turn the tap to the low flame position.

 

 

2. Remove the knob and adjust

 

the adjustment screw, which is

 

positioned in or next to the tap

 

pin, until the flame is small but

 

steady.

3.Having adjusted the flame to the required low setting, while the burner is alight, quickly change the position of the knob from minimum to maximum and vice versa several times, checking that the flame does not go out.

4.Some appliances have a safety device (thermocouple) fitted. If the device fails to work when the burners are set to the low flame setting, increase this low flame setting using the adjusting screw.

5.Once the adjustment has been made, replace the seals on the by-passes using sealing wax or a similar substance.

!If the appliance is connected to liquid gas, the regulation screw must be fastened as tightly as possible.

!Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Stickers are available from any of our Service Centres.

!Should the gas pressure used be different (or vary slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet pipe (in order to comply with current national regulations).

DATA PLATE

Electrical

connections see data plate

This appliance conforms to the following European Economic Community directives: - 2006/95/EEC dated 12/12/06 (Low Voltage) and subsequent amendments

- 2004/108/EEC dated 15/12/04 (Electromagnetic Compatibility) and subsequent amendments

- 93/68/EEC dated 22/07/93 and subsequent amendments.

- 2009/142/EEC dated 30/11/09 (Gas) and subsequent amendments.

- 2002/96/EC and subsequent amendments.

PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24

4

Page 4
Image 4
Hotpoint GP641X Setting the burners to minimum, Turn the tap to the low flame position, steady, DATA PLATE Electrical