•Setting the burners to minimum:

4. Once this procedure is finished, replace the old rating

GB sticker with one indicating the new type of gas used. Sticker are available from any of our Service Centres.

Adjusting the burners’ primary air : Does not require adjusting.

Setting the burners to minimum:

1.Turn the tap to the low flame position.

2.Remove the knob and adjust the adjustment screw, which is positioned in or next to the tap pin, until the flame is small but steady.

3.Having adjusted the flame to the required low setting, while the burner is alight, quickly change the position of the knob from minimum to maximum and vice versa several times, checking that the flame does not go out.

4.Some appliances have a safety device (thermocouple) fitted. If the device fails to work when the burners are set to the low flame setting, increase this low flame setting using the adjusting screw.

5.Once the adjustment has been made, replace the seals on the by-passes using sealing wax or a similar substance.

￿If the appliance is connected to liquid gas, the regulation screw must be fastened as tightly as possible.

￿Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Stickers are available from any of our Service Centres.

￿Should the gas pressure used be different (or vary slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet pipe (in order to comply with current national regulations).

DATA PLATE

Electrical connections

See data plate

This appliance conforms to the following European Economic Community directives: -73/23/EEC dated 19/02/73 (Low Voltage) and subsequent amendments

-89/336/EEC dated 03/05/89 (Electromagnetic Compatibility) and subsequent amendments

-93/68/EEC dated 22/07/93 and subsequent amendments.

-90/336/EEC dated 29/06/90 (Gas) and subsequent amendments.

-2002/96/EC