GB Installation

The installation procedure is illustrated in the first pages of this manual.

The installation must be done by a qualified technician.

Electrical hook up

The mains voltage must match that given on the ratings label inside the hood itself. If the hood has a power plug, connect the hood to an easily accessible regulatory power socket. If it does not (direct connection to the mains), or the socket is not easily accessible, install a two-pole regulatory switch to enable total disconnection from the mains in case of category III overvoltage, as required by the installation regulations.

Caution! Always check that the mains cable is hooked up properly and check that it operates correctly before reconnecting the hood to the mains.

Air exhaust (for ducted units)

Connect the hood to a duct and wall exhaust hole of a diameter equal to that of the air outlet flange. Using a smaller diameter tube and exhaust hole reduces the extraction capacity of the hood and also increases its running noise. The manufacturer is not liable for any consequences of doing so.

!Use the shortest duct required to achieve the purpose.

!Use a duct with as few bends as possible

!Avoid suddenly changing the diameter of the duct.

!The duct must have as smooth an inner surface as possible.

!The duct must be made of regulatory material.

!Do not connect the hood to flues carrying combustion fumes from other equipment (boilers, chimneys, stoves, etc.).

!Observe the instructions of the competent authorities in relation to the air exhaust. The air being exhausted may not be exhausted into a wall cavity unless the cavity in question is specifically intended for this purpose.

!Equip the room with air intakes to prevent the hood creating suction pressure in the interior (this must not exceed 0.04 mbar).

!The manufacturer is not liable for any consequences of failure to observe these instructions.

Filter or ducted?

!Your hood is supplied as a ducted unit.

If you wish to use it as a filter unit, you must install the proper

ACCESSORY KIT.

Note: If supplied with the hood, the accessory active charcoal filter unit may already be installed.

Instructions for transforming the hood from the ducted to the filter version are given in this manual (see “Filter version”).

Ducted version

The hood purifies the air and expels it outdoors via an exhaust duct (dia. 150mm) connected to its outlet flange. The diameter of the exhaust tube must be equal to that of the outlet flange.

Caution! The exhaust duct is not supplied and must be purchased separately.

When routed horizontally, the tube must be angled slightly upwards (around 10°) to enable the air to be conveyed outdoors more easily. If the hood is fitted with charcoal filters, they must first be removed.

Filter version

The hood purifies the air and returns it to the room. This version of the hood requires installation of an accessory active charcoal filter unit.

This version requires an air deflector, a reduction adapter and the charcoal filter/s. The top tube must have its air outlet slots uppermost.

Technical data

 

Height

Width

Depth

dia. of

Model

exhaust tube

(cm)

(cm)

(cm)

 

(cm)

 

 

 

 

TBOX-GLASS 90cm

61-82

89.9

50

15/12

 

 

 

 

 

Please check the plate in order to verify the total absorption and the light absorption

LED Risk Group 1 according to Standard EN 62471

The model is in accordance with the following EU directives::

“Low voltage” Directive 2006/95/EC (12-12-2006)

“EMC” Directive 2004/108/EC (15-12-2004)

UR Reference no. 66/2014 integrating Directive no. 2009/125/EC.

Reference standard:

EN 60704-2-13:2011; EN 60704-3:2006

EN 61591:1997; EN 61591:1997/A1:2006; EN 61591:1997/ A2:2011; EN 61591:1997/A11:2014

EN 50564:2011