Hotpoint SBS 638 CX S Electrical Connection, Voltage Frequency see data plate

Models: SBS 638 CX S

1 16
Download 16 pages 37.38 Kb
Page 5
Image 5
Electrical Connection:

Electrical Connection:

Voltage Frequency: see data plate

Fuse Section: 16A

Supply cable: 3x1.5mm2

You can connect your oven to the system means of a terminal board. Refer to above information for the minimal cable sections and the calibration of the protective elements according to the connection.

If the appliance is installed with a junction box, an omnipolar circuit breaker

-with a minimum contact opening of 3mm - should be installed between the appliance and the mains.

Powercablesupplyconnectiontotheelectricalmains:

We recommend you use a power supply cable which is long enough to allow you to take the oven out of its recess in the event of maintenance operations (only use HAR - H 05 - RRF quality cables fitted with a plug conforming to the regulations in force.

The plug must be accessible at all times.

Unplug the appliance before all operations, even when replacing the oven lamp.

Using the appliance without correct earthing is highly dangerous.

!After connecting the appliance to the flexible cable, tighten all the screws on the terminal board.

APPLIANCE SPECIFICATIONS

Dimensions*

width 43.5 cm

height 32,4 cm

 

depth 41.5 cm

Volume*

59 l

 

 

 

 

 

Dimensions**

width 45.5 cm

height 32,4 cm

 

depth 41.5 cm

Volume**

62 l

 

 

 

 

 

Electrical

voltage: 230-240V~ 50/60Hz

connections

(see data plate) maximum power

 

absorbed 2800-3000 W

 

EU Directive no 65/2014

 

supplementing Directive 2010/30/EU.

 

EU Regulation no 66/2014

Energy

implementing Directive 2009/125/EC.

Standard EN 60350-1

Label e

Standard EN 50564

Ecodesign

Energy consumption for Natural

 

 

convection – heating mode:

 

Traditional mode

 

 

 

 

 

Declared energy consumption for

 

Forced convection Class

 

mode:

Baking

This appliance conforms to the following European Economic Community directives:

-2006/95/EC dated 12/12/06 (Low Voltage) and subsequent amendments.

- 2004/108/EC dated 03/05/89 (Electromagnetic Compatibility) and subsequent amendments.

- 93/68/EEC dated 22/07/93 and subsequent amendments.

-2012/19/EU and subsequent amendments.

*Only for models with drawn rails.

**Only for models with wire rails.

GB

PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24

5

Page 5
Image 5
Hotpoint SBS 638 CX S Electrical Connection, Voltage Frequency see data plate, Fuse A Supply cable 3x1.5mm2