Adapting to the gas in use

GB

Adapting to the gas in use

It is possible to use other types of gas by adapting the burner adjustment as follows: Make sure that the oven is not connected to the electric power supply.

Open the oven door completely and remove the oven bottom unscrewing the screws. Remove the burner by unscrewing its screw, then unscrew the injector and replace it. Reassemble the burner in the oven and the oven bottom.

Changing the grill burner injector (fig. 2-3)

Make sure that the oven is not connected to the electric power supply. Open the oven door completely.

Remove the grill burner by unscrewing its screws, then unscrew the injector and replace it.

Reassemble the burner.

Fig. 2

Fig. 3