GB

The wires in the mains supply lead are coloured in accordance with the following code: Green and Yellow - Earth

Blue - Neutral

Brown –Live

The connection must be made as follows:

The wire coloured Green and Yellow must be connected to the

terminal marked ‘E’ or the earth symbol Α or coloured green or green and yellow. The wire coloured Blue must be connected to the terminal marked

‘N’ or coloured blue or black.

The wire coloured Brown must be connected to the terminal marked ‘L’ or coloured brown or red.

NOTE: The terminals marked ‘SUPPLY’ are for the mains supply wires and the terminations marked ‘LOAD’ are for the appliance wires. The electrical outlet is to be positioned in an easily accessible position adjacent to the appliance. In the event that it is necessary to replace the mains lead, the replacement must conform to the specification listed in the Technical Data ensuring the correct colour code connection and that all screws are tightened sufficiently.

7

Page 8
Image 8