Image 18

Installation Instructions

Technical Data

Dimension

General

Height

900mm

Width

500mm

Depth

600mm (excluding door handles)

Gas connection

Rp 1/2 (1/2” BSP female)

Pressure test point

Grill injector

Gas rate adjustment

None

Aeration adjustment

None

Battery (Model X156G):

1.5V Alkaline AA

Electrical connection

flexible cord fitted with 3 pin 13AMP

plug, (Model 5TCG):

230/240V a.c. 50Hz 3A fuse

Natural Gas

BURNER

HEAT INPUT

INJECTOR

 

 

 

HOTPLATE

3.0 kW

128

Front left

 

 

 

 

 

HOTPLATE

2.0 kW

102

Rear left

 

 

 

 

 

HOTPLATE

1.0 kW

72

Rear right

 

 

 

HOTPLATE

2.0 kW

102

Front right

 

 

 

 

 

GRILL

3.8 kW

150

 

 

 

OVEN

2.5 kW

115

 

 

 