Table A-1.

HP PCL 5 Commands (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTION

PARAMETER

COMMAND

DECIMAL VALUE

 

HEXADECIMAL VALUE

 

 

STATUS READBACK

 

 

 

 

 

 

Set Status Readback Location Type

Invalid Location

?*s0T

(t)

027 042 115 048 084

(116)

1B

2A

73 30 54

(74)

 

 

Currently Selected

?*s1T

(t)

027 042 115 049 084

(116)

1B

2A

73 31 54

(74)

 

 

All Locations

?*s2T

(t)

027 042 115 050 084

(116)

1B

2A

73 32 54

(74)

 

 

Internal

?*s3T

(t)

027 042 115 051 084

(116)

1B

2A

73 33 54

(74)

 

 

Downloaded

?*s4T

(t)

027 042 115 052 084

(116)

1B

2A

73 34 54

(74)

 

 

Cartridge

?*s5T

(t)

027 042 115 053 084

(116)

1B

2A

73 35 54

(74)

 

 

User-installed ROM (SIMMs)

?*s7T

(t)

027 042 115 055 084

(116)

1B

2A

73 37 54

(74)

Set Status Readback Location Unit

All entities of the Location Type

?*s0U

(u)

027 042 115 048 085

(117)

1B

2A

73 30 55

(75)

 

 

Entity 1 or Temporary

?*s1U

(u)

027 042 115 049 085

(117)

1B

2A

73 31 55

(75)

 

 

Entity 2 or Permanent

?*s2U

(u)

027 042 115 050 085

(117)

1B

2A

73 32 55

(75)

 

 

Entity 3

?*s3U

(u)

027 042 115 051 085

(117)

1B

2A

73 33 55

(75)

 

 

Entity 4

?*s4U

(u)

027 042 115 052 085

(117)

1B

2A

73 34 55

(75)

Inquire Status Readback Entity

Font

?*s0I

(i)

027 042 115 048 073

(105)

1B

2A 73 30 49

(69)

 

 

Macro

?*s1I

(i)

027 042 115 049 073

(105)

1B

2A 73 31 49

(69)

 

 

User-defined Pattern

?*s2I

(i)

027 042 115 050 073

(105)

1B

2A 73 32 49

(69)

 

 

Symbol Set

?*s3I

(i)

027 042 115 051 073

(105)

1B

2A 73 33 49

(69)

 

 

Font Extended

?*s4I

(i)

027 042 115 052 073

(105)

1B

2A 73 34 49

(69)

Flush All Pages

 

Flush All Complete Pages

?&r0F

(f)

027 038 114 048 070

(120)

1B

26 72 30 46

(66)

 

 

Flush All Page Data

?&r1F

(f)

027 038 114 049 070

(120)

1B

26 72 31 46

(66)

Free Memory Space

?*s1M

(m)

027 042 115 049 077

(109)

1B

2A

73 31 4D

(6D)

Echo

 

# = Echo value (-32767 to 32767)

?*s#X

(x)

027 042 115 #...# 088

(120)

1B

2A

73 #...# 58

(78)

 

 

PROGRAMMING HINTS

 

 

 

 

 

 

End-of-Line Wrap

Enabled

?&s0C

(c)

027 038 115 048 067

(99)

1B

26 73 30 43

(63)

 

 

Disabled

?&s1C

(c)

027 038 115 049 067

(99)

1B

26 73 31 43

(63)

Display Functions

ON

?Y

 

027 089

 

1B

59

 

 

 

 

OFF

?Z

 

027 090

 

1B

5A

 

 

A-16 Printer Commands