QuickSpecs

HP StorageWorks 2000fc G2 Modular Smart Array

Family Information

Workload

MSA2300fc

MSA2000sa

MSA2000i

Host Connect

4 Gb Fibre

3 Gb SAS

1GbE Ethernet

Channel

 

 

 

MSA2000 RAID 10 Performance Results (rounded)

 

Random Reads IOPs

21,400

10,600

8,200

Random Writes IOPs

8,800

4,900

4,500

Random Mix IOPs 60/40

13,500

6,800

6,100

read/write

 

 

 

Sequential Reads MB

1,300

700

300

Sequential Writes MBs

560

350

260

MSA2000 RAID 5 Performance Results (rounded)

 

Random Reads IOPs

20,500

10,200

7,800

Random Writes IOPs

2,400

2,000

1,600

Sequential Reads MBs

1,300

700

300

Sequential Writes MBs

780

380

270

Random Mix IOPs

5,900

3,300

3,200

60/40 read/write

 

 

 

MSA2000 RAID 6 Performance Results (rounded)

 

Random Reads IOPs

20,500

10,100

7,800

Random Writes IOPs

1,600

1,400

1,200

Sequential Reads MBs

1,300

700

300

Sequential Writes MBs

820

380

270

Random Mix IOPs 60/40

4,500

2,750

2,560

read/write

 

 

 

DC-power chassis HP is making the two models of controller-less chassis available with direct current (DC) power supplies. They each have the two empty bays where users can insert one or two MSA2300fc G2 controller(s). In addition, the MSA2012 LFF drive bay can have MSA2000 3.5-inch I/O modules inserted to create a LFF DC-power JBOD.

The 500 watt power supply is designed to operate over the input range of - 40VDC to -75VDC. This is specifically intended to conform to Telco requirements. Certification is in process but no claims are made at this time.

HP StorageWorks 2012 Modular Smart Array 3.5-in

AJ950A

Drive Bay DC-power Chassis (LFF)

 

HP StorageWorks 2024 Modular Smart Array 2.5-in

AJ951A

Drive Bay DC-power Chassis (SFF)

 

Configuration and HP StorageWorks MSA Storage Management Utility (SMU). Management

Management Tools access, out-of-band: WEB GUI, CLI. Interface Types: Mini DB9 RS232, 10/100 Ethernet Protocols Supported SNMP, SSL, SSH, SMTP, HTTP, Telnet

Hot Plug Expansion and All MSA2000 models support hot plug expansion and replacement of Replacement Support redundant controllers, enclosures, fans, power supplies, and I/O modules for

simple, fast installation and maintenance.

Snapshot and Clone Optional controller based functionality. Offers higher levels of data protection, enabling an almost instant recovery from data failure or corruption. Offers alternative development testing of 'offline' production data and the ability to backup snapped/cloned data.

DA - 13187 EMEA — Version 2 — February 10, 2009

Page 8

Page 8
Image 8
HP 2000fc manual Workload MSA2300fc MSA2000sa MSA2000i Host Connect, MSA2000 RAID 10 Performance Results rounded