Mount Gun

Reciprocating Arm Rod Mount

Manifolds 241161 and 241162

To mount the gun on a reciprocating arm rod [0.5 in. (13 mm) diameter maximum]:

1.Insert the mounting bar (A) through the hole in the manifold as shown in FIG. 3.

Use the 1/8 in. alignment pin (P) to assist in orienting the gun.

2.Secure the gun to the bar by tightening the mount- ing screw (B).

3.Ensure the tip of the gun is 8 to 10 in. (150 to 200 mm) from the surface of the object being sprayed.

B

P

A

TI8111a

FIG. 3: Reciprocating Arm Mount

Installation

Stationary Support Mount

All Manifolds

To mount the gun on a stationary support (refer to FIG.

4.and Mounting Hole Layout, page 28):

1.Attach the gun to the support with two M5 x 0.8 cap- screws (C). The screws must be long enough to engage the threaded holes in the gun manifold to a depth of 1/4 in. (6 mm).

2.Ensure the tip of the gun is 8 to 10 in. (150 to 200 mm) from the surface of the object being sprayed.

CTI8112a

FIG. 4: Stationary Support Mount

311053C