Manual Changes/Model 6205B

TM 11-6625-2965-14&P

 

 

 

 

 

 

 

HP PART NO.

 

DESCRIPTION

 

STANDARD

OPTION A85

OPTION X95

 

 

 

 

Front Panel, Lettered

06205

-00005

 

0 6 2 0 5 - 6 0 0 0 4

 

 

 

 

Chassis,

Right

Side

5060

-7956

 

 

5060-6118

Chassis,

Left

Side

5060

-7955

 

 

5060-6119

Cover, Top

 

5000

-9424

 

 

5000-6061

Rack Kit

(accessory)

 

14523A

1 4 5 2 3 A - A 8 5

 

Heatsink

 

 

06205-60005

 

 

06205-60002

 

 

 

 

 

 

 

 

 

ERRATA:

 

 

 

 

 

ERRATA:

 

 

 

 

 

 

 

 

In parts list, change HP Part No. of rubber bumper (qty. 4) to 0403-0002.

In Figure 5-4,change Rx value listed for Model 6206B to 3 ohms.

In Table 1-1,change the INTERNAL IMPEDANCE AS A CONSTANT VOLTAGE SOURCE (Output Impe- dance) specification to read as follows:

Output Impedance (Typical): Approximated by a 25 milliohm resistance in series with a 1 micro henry inductance.

The standard colors for this instrument are now mint gray (for front panel) and olive gray (for all other external surfaces). Option X95 designates use of the former color scheme of light gray and blue gray. Option A85 designates use of a light gray front panel with olive gray used for all other external surfaces. New part numbers shown above.

In Figure 3-9, delete the six references to TP23. These wires must be connected in the appropriate power supply directly to the end of R54 that is towards the rear of the supply. Another correction needed in this figure is that the wire from terminal A6 in Slave No. 1 in the two-unit example at the top of the figure should be connected to the rear of R54 in the master supply. Note: The range switches of the master and slave supplies must be set to the same range when operating in auto- parellel.

Add to the parts list the replacement lamp for illuminated switch 3101-1248, which is used in those supplies that include Change 2. The HP Part No. of the type A1H lamp is 2140-0244.

Effective January 1, 1977, Option 007 (1O-turn voltage control) has been redesignated Option 009, and Option 013 (1 O-turn voltage control with deca - dial) has been redesignated Option 015. Make these changes wherever Option 007 or 013 is mentioned in the manual.

The front panel binding posts have been changed to a type with better designed insulation. Delete the two types of posts listed on page 6-6 of the parts list and add : black binding post, HP Part No. 1510- 0114 (qty. 4); and red binding post HP Part No.

1510-0115 (qty. 2).

The corrugated shipping carton for this model has been changed to HP Part No. 9211-2570. Two 9220-2703 floater pads are used.

The blue-gray meter bezel has been replaced by a black one, HP Part No. 4040-0414.

8-5-77

D-6