2.5 Specifications
This section includes the environmental, electrical, and physical specifications for the systems covered in this guide. Where provided, metric statistics are given in parenthesis. Specifications are subject to change without notice.
Table
Parameter | Operating |
Ambient Air Temperature 50o to 95o F (10o to 35o C, max. rate of change < 10°C/Hr)
rate of change < 20°C/Hr )
Shock (w/o damage) |
| 5 Gs [1] | 20 Gs [1] |
|
|
|
|
Vibration | 0.000215 | G2/Hz, | 0.0005 G2/Hz, |
|
|
|
|
Humidity | Rh @ 28o C max. | ||
| wet bulb temperature | wet bulb temperature | |
|
|
| |
Maximum Altitude | 10,000 ft (3048 m) [2] | 30,000 ft (9144 m) [2] |
NOTE:
[1]Peak input acceleration during an 11 ms
[2]Maximum rate of change: 1500 ft/min.
Table
Parameter | U.S. | International |
|
|
|
Input Line Voltage: |
|
|
Nominal: | ||
Maximum: | ||
|
|
|
Input Line Frequency Range: |
|
|
Nominal: | ||
Maximum: | ||
|
|
|
Power Supply: |
|
|
Maximum Continuous Power: |
|
|
USDT | 200 watts | 200 watts |
ST or SFF | 240 watts | 240 watts |
MT/CMT | 365 watts | 365 watts |
Maximum Line Current Draw: |
|
|
USDT | 4 A @ 100 VAC | 2 A @ 200 VAC |
SF or SFF | 5 A @ 100 VAC | 2.5 A @ 200 VAC |
MT/CMT | 6 A @ 100 VAC | 3.0 A @ 200 VAC |
|
|
|
. |
|
|
| www.hp.com | Technical Reference Guide |