System Overview

2.5 Specifications

This section includes the environmental, electrical, and physical specifications for the systems covered in this guide. Where provided, metric statistics are given in parenthesis. Specifications are subject to change without notice.

Table 2-7

Environmental Specifications (Factory Configuration)

Parameter

Operating

Non-operating

Ambient Air Temperature 50o to 95o F (10o to 35o C, max. rate of change < 10°C/Hr)

-22oto 140o F (-30oto 60o C, max.

rate of change < 20°C/Hr )

Shock (w/o damage)

 

5 Gs [1]

20 Gs [1]

 

 

 

 

Vibration

0.000215

G2/Hz, 10-300 Hz

0.0005 G2/Hz, 10-500 Hz

 

 

 

 

Humidity

10-90%

Rh @ 28o C max.

5-95% Rh @ 38.7o C max.

 

wet bulb temperature

wet bulb temperature

 

 

 

Maximum Altitude

10,000 ft (3048 m) [2]

30,000 ft (9144 m) [2]

NOTE:

[1]Peak input acceleration during an 11 ms half-sine shock pulse.

[2]Maximum rate of change: 1500 ft/min.

Table 2-8

Electrical Specifications

Parameter

U.S.

International

 

 

 

Input Line Voltage:

 

 

Nominal:

100–240 VAC

100–240 VAC

Maximum:

90–264 VAC

90–264 VAC

 

 

 

Input Line Frequency Range:

 

 

Nominal:

50–60 Hz

50–60 Hz

Maximum:

47–63 Hz

47–63 Hz

 

 

 

Power Supply:

 

 

Maximum Continuous Power:

 

 

USDT

200 watts

200 watts

ST or SFF

240 watts

240 watts

MT/CMT

365 watts

365 watts

Maximum Line Current Draw:

 

 

USDT

4 A @ 100 VAC

2 A @ 200 VAC

SF or SFF

5 A @ 100 VAC

2.5 A @ 200 VAC

MT/CMT

6 A @ 100 VAC

3.0 A @ 200 VAC

 

 

 

.

 

 

 

2-24

www.hp.com

Technical Reference Guide