QuickSpecs

HP Compaq dx7500 Business PC

 

 

 

System Details

 

 

 

Power Supply

MT: 300-watt ATX Power Supply – PFC/non-PFC with a 115v/230v line

 

 

switch (varies by country/region)

 

 

SFF: 250-watt Power Supply – PFC with a 115/230v line switch.

 

 

 

 

Unit Environment and Operating Conditions

General Unit Operating Guidelines

Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is operated within the specified operating range.

Leave a 4 in (10.2 cm) clearance on all vented sides of the computer to permit the required airflow.

Never restrict airflow into the computer by blocking any vents or air intakes.

Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-circulated or preheated air.

Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign matter can block the vents and limit the airflow.

If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure, and the same operating guidelines listed above will still apply.

Temperature Range (MT)Operating

41° to 95° F (5° to 35° C)

 

Non-operating

–22° to 140° F (–30° to 60° C)

Relative Humidity (MT)

Operating

15% to 80% (non-condensing at ambient)

 

Non-operating

90% (non-condensing at ambient)

Maximum Altitude (MT) Operating

7500 ft (2286 m)

(unpressurized)

Non-operating

15,000 ft (4572 m)

Temperature Range (SFF)Operating

50° to 95° F (10° to 35° C)

 

Non-operating

–22° to 140° F (–30° to 60° C)

Relative Humidity (SFF) Operating

10% to 90% (non-condensing at ambient)

 

Non-operating

5% to 95% (non-condensing at ambient)

Maximum Altitude (SFF) Operating

10,000 ft (3048 m)

(unpressurized)

Non-operating

30,000 ft (9000 m)

NOTE: Operating temperature is de-rated 1.0 deg C per 1000 ft (300 m) to 7500 ft (2286 m) for MT and 10000 ft (3000m) for SFF above sea level, no direct sustained sunlight. Maximum rate of change is

7.5deg C/Hr for MT and 10 deg C/Hr for SFF. The upper limit may be limited by the type and number of options installed.

System Board

Processor

Socket T; LGA775 industry standard Micro ATX form factor

 

 

Support single Intel Core 2 Duo and Core 2 Quad, Pentium dual-core, or

 

 

Celeron processors

 

PWM

ON – NCP5362 – 3 phase

 

Chipset

Intel G45 Express

 

 

Intel I/O Controller Hub 10 (ICH10R)

 

Super I/O

Fintek F8000

Front Side Bus Frequency800/1066/1333 MHz

DA - 13152 Worldwide QuickSpecs — Version 9 — 3/30/2009