FP USER INSTRUCTIONS ENGLISH 71576286 - 07/06
Maximum working pressure at discharge
Maximum................................................................working pressure at suction | 25 bars |
16 bars | |
except | 10 bars |
Maximum pumped fluid temperature ...... | 105 °C |
impeller and diffuser for CAST IRON or BRONZE. | |
Minimum pumped fluid temperature ....... | |
Maximum ambient temperature .............. | 40 °C |
Maximum solid suspension ..................... | 50 g/m3 |
Density........................................................... | 1 |
Viscosity .............................................. | 1 mm²/s |
Frequency ................. | 50 Hz (1450 - 2900 min- 1) |
................................... | 60 Hz (1750 - 3500 min- 1) |
Maximum number of stages (according to rotation speed)
| 3500 | 2900 | 1750 | 1450 |
| ||||
50 FP | 6 | 7 | 7 | 7 |
|
|
|
|
|
65 FP | 4 | 6 | 7 | 7 |
|
|
|
|
|
80 FP | 3 | 5 | 6 | 6 |
|
|
|
|
|
100 FP | 3 | 5 | 6 | 6 |
|
|
|
|
|
122 FP |
|
| 4 | 5 |
|
|
|
|
|
125 FP | 2 | 3 | 4 | 5 |
|
|
|
|
|
152 FP & 202 |
|
| 3 | 4 |
FP |
|
| ||
|
|
|
|
The maximum speed is shown on the pump nameplate.
3.2 Nomenclature
Characteristics shown on the nameplate fixed on the pump are as shown below:
Each pump is supplied with the following nameplate:
Speed of rotation
Pump type
Flow rate
Head
Radial/thrust bearing
Year of construction +
Manufacture number
Mass
Maximum admissible Pressure at 20 °C
Maximum / minimum temperature
Each pump unit is supplied with the following nameplate:
Mass of the set
Page 12 of 35