FP USER INSTRUCTIONS ENGLISH 71576286 - 07/06

Maximum working pressure at discharge

 Maximum................................................................working pressure at suction

25 bars

16 bars

except 122-152 and 202 FP....................

10 bars

 Maximum pumped fluid temperature ......

105 °C

impeller and diffuser for CAST IRON or BRONZE.

 Minimum pumped fluid temperature .......

-10 °C

 Maximum ambient temperature ..............

40 °C

 Maximum solid suspension .....................

50 g/m3

 Density...........................................................

1

 Viscosity ..............................................

1 mm²/s

 Frequency .................

50 Hz (1450 - 2900 min- 1)

...................................

60 Hz (1750 - 3500 min- 1)

Maximum number of stages (according to rotation speed)

 

3500

2900

1750

1450

 

min-1

min-1

min-1

min-1

50 FP

6

7

7

7

 

 

 

 

 

65 FP

4

6

7

7

 

 

 

 

 

80 FP

3

5

6

6

 

 

 

 

 

100 FP

3

5

6

6

 

 

 

 

 

122 FP

 

 

4

5

 

 

 

 

 

125 FP

2

3

4

5

 

 

 

 

 

152 FP & 202

 

 

3

4

FP

 

 

 

 

 

 

The maximum speed is shown on the pump nameplate.

3.2 Nomenclature

Characteristics shown on the nameplate fixed on the pump are as shown below:

Each pump is supplied with the following nameplate:

Speed of rotation

Pump type

Flow rate

Head

Radial/thrust bearing

Year of construction +

Manufacture number

Mass

Maximum admissible Pressure at 20 °C

Maximum / minimum temperature

Each pump unit is supplied with the following nameplate:

Mass of the set

Page 12 of 35