FP USER INSTRUCTIONS ENGLISH 71576286 - 07/06

Example of straight

Example of bevel cut

Ensure a tightening on the stuffing box housing and not on the sleeve.

SETTING OF PACKING

Follow the instructions:

a)Assemble of the packing in S.

b)Stagger by about 90° between two rings.

c)Assemble packing after packing.

After setting the last packing ring, secure the packing with the gland and tighten the nut by hand. After tightening, the shaft should turn by hand as easily as before the setting of the packing.

 

PUMP

 

 

DIMENSIONS IN MILLIMETERS

 

PACKING

 

 

 

 

 

 

 

 

 

 

 

 

 

TYPE

 

 

D1

D2

D3

D4

D5

L1

 

Lgth

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 FP

24

30

46

70

M10

48

600

8

 

 

 

 

 

 

 

 

 

 

 

65 FP

24

30

46

70

M10

48

600

8

 

 

 

 

 

 

 

 

 

 

 

80 FP

32

40

60

86

M12

63

800

10

 

 

 

 

 

 

 

 

 

 

 

100 FP

32

40

60

86

M12

63

800

10

 

 

 

 

 

 

 

 

 

 

 

122 FP

45

55

75

100

M12

45

850

10

 

 

 

 

 

 

 

 

 

 

 

125 FP

40

50

70

96

M12

60

1000

10

 

 

 

 

 

 

 

 

 

 

 

152 FP

55

70

95

135

M12

78

1100

12

 

 

 

 

 

 

 

 

 

 

 

202 FP

65

80

109

150

M16

91

1200

14

 

 

 

 

 

 

 

 

 

 

 

 

 

For arrangement of packing, see section 8.1, Sectional drawings.

6.2.6 Internal coating

If the pump has an internal coating, this coating must be inspected periodically. Any wear or cracks of the coating found must be immediately repaired. Failure to do this may lead to accelerated wear of the coating during operation and corrosion of the exposed base metal, depending on the material and pumped liquid. Special attention must be paid to the coating edges. Any loss of coating material is considered to be normal wear and tear on the pump and is not considered as warranty. Flowserve has applied the coatings according to the supplier's instructions but will not be held responsible for coating wear or cracks that may develop over time.

6.3 Spare parts

6.3.1 Ordering of spares

Flowserve keeps records of all pumps that have been supplied. When ordering spares the following information should be quoted:

1)Pump serial number.

2)Pump size.

3)Part name

4)Part number

5)Number of parts required.

The pump size and serial number are shown on the pump nameplate.

To ensure continued satisfactory operation, replacement parts to the original design specification should be obtained from Flowserve. Any change to the original design specification (modification or use of a non-standard part) will invalidate the pump’s safety certification.

Page 24 of 35