QuickSpecs
HP MSA P2000 G3 Modular Smart Array Systems
Family Information
MSA2000 models. The
Optional Disk enclosures Just as the user has a choice of chassis for the array head (LFF and SFF drive bays, AC or DC powered), so also do they have a choice of expansion disk enclosures accommodating either drive size. Both the P2000 and the D2700 disk enclosures can be
(NOTE: these are not supported as part of a
P2000
This
Up to seven P2000
| D2700 |
| ProLiant |
| modules installed. |
| This |
| The D2700 enclosure ships with a two .5m miniSAS to miniSAS cable. |
| Up to five D2700 may be attached to the P2000 G3 array head, given total support for 149 SFF drives. |
Scalability | The P2000 G3 FC, Combo FC/iSCSI, SAS, 1 Gb or 10GbE iSCSI controllers are designed to allow an installation |
| to begin with smaller capacity and be able to grow gradually as needed. The flexibility of SAS or SATA drive |
| technology, form factors, sizes, speeds, and costs per GB allows a system to easily fit in almost any budget. |
| Large Form Factor configurations can scale up to 7.2 TB SAS, 36TB SAS MDL or 24 TB SATA, |
| expandable to 57.6 TB SAS, 384 TB SAS MDL or 192 TB SATA with the addition of a maximum of seven |
| P2000 |
| Small Form Factor configurations can scale from 21.6 TB SAS, 24 TB SAS MDL or 12 TB SATA MDL. |
| With the addition of five D2700 JBODs, the P2000 G3 can support 134 TB SAS, 149 TB SAS MDL or |
| 74.5 TB SATA MDL. |
| Users may configure a |
| enclosures. This is an excellent method for a configuration that supports fast SFF |
| SAS drives in the array head, combined with economical LFF drives staged for archival purposes, all in |
| the same array. |
| Qualification of larger capacity drives is ongoing. |
Vdisks | Vdisks can span across multiple enclosures, where drives used in the Vdisk can be contained in different |
| enclosures. The maximum number of drives that can be used in RAID 1 Vdisk is 2; RAID 0, 3, 5, 6, and 10 is |
| 16; and for RAID 50 Vdisk is 32. |
LUNs | The HP 2000 family of arrays supports 512 LUNs (total volumes in a dual controller system) and LUN sizes |
| up to 64 TB depending on the RAID configuration chosen. The array supports expansion and deletion of any |
| LUN. |
RAID 0, 1, 3, 5, 6, 10, 50 In addition to the usual RAID levels, the P2000 G3 features several important additional levels. RAID 6 is the highest level of RAID protection. It allocates two sets of parity data across drives and allows simultaneous write operations. It can withstand two simultaneous drive failures without downtime or data loss. RAID 10 is mirroring and striping without parity. It is the most popular of the multiple RAID levels, allowing large arrays with high performance in most cases and superior fault tolerance. RAID 50 combines the block striping and parity of RAID 5 with the straight block striping of RAID 0, yielding higher performance than RAID 5 through
DA - 13551 North America — Version 36 — December 9, 2013 | Page 13 |