QuickSpecs
HP MSA P2000 G3 Modular Smart Array Systems
Family Information
8Gb Fibre Channel | Two host ports per FC controller shipped with SFPs. The P2000 G3 FC controller can run in either | ||
controller | point or FCAL (loop). The default is FCAL which is used in Direct Connect, particularly with two controllers. | ||
| The PtP (fabric) mode is used with almost all switches. |
|
|
Combo controller with | This ingenious | ||
FC and iSCSI ports | designating the two 1 GbE iSCSI ports to enable remote replication over iSCSI protocol and perform as an | ||
| iSCSI target. This allows economical sharing of the storage resource (the P2000 G3 array) with one | ||
| department needing the performance afforded by the 8 Gb FC ports while simultaneously supporting | ||
| another department with lesser performance needs and a budget only allowing a 1GbE iSCSI network. | ||
6Gb SAS controller | Four 4x host ports per 6Gb SAS controller. |
|
|
10GbE iSCSI controller | Two 10GbE ports per G3 10GbE iSCSI controller. Ports are ready for the choice of SFP (none included) | ||
| Supports the ProCurve and ISS versions of the following 10GbE parts for use in the controllers: |
|
|
| HP 10Gb Cables |
|
|
| HP SFP+ 10GbE Copper Cable |
|
|
| HP ProCurve |
|
|
| HP SFP+ Transceivers |
|
|
| HP BladeSystem 10Gb SR SFP+ and HP BladeSystem 10Gb LRM SFP+ |
|
|
| HP ProCurve |
|
|
| No SFP+ LR Transceiver support |
|
|
1 Gb iSCSI controller | Four 1 Gb Ethernet iSCSI ports per G3 iSCSI controller |
|
|
Modular Chassis | 2U rack height. 12 Large Form Factor or 24 Small Form Factor drive bays, accommodating SAS and SATA. | ||
| Comes with space for one or two controllers, or P2000 | ||
| only) |
|
|
Drives available | The P2000 G3 controllers support both the P2000 | ||
| Storage |
|
|
| Serial Attached SCSI (SAS) | ||
| SAS Midline and SATA Midline are usually reserved for archival of data as they are both relatively | ||
| inexpensive and are available in very large capacities. |
|
|
| The HP | ||
| making it ideal to have both | ||
| or Remote Snap capability to keep |
|
|
| For investment protection, the controllers will support single and dual port SAS & SATA drives in a legacy | ||
| single - or dual - domain MSA70. This support allows current owners of MSA70s to migrate their single port | ||
| drives (in their MSA70 only, not into the array head) to be attached to a P2000 G3 FC or SAS. They can only | ||
| cascade to another single I/O MSA70. This is not a | ||
| be impacted. |
|
|
| SAS drive performance can be approximately 30% greater than SATA performance on sequential host I/O. | ||
| SAS performance excels in sequential lower latency response time and random I/O per second transaction | ||
| performance due to higher rpm disk speeds yielding lower seek times. SAS drive random performance is | ||
| generally twice that of SATA drives. |
|
|
| NOTE: P2000 and MSA2 | ||
|
|
|
|
| DA - 13551 North America — Version 36 — December 9, 2013 | Page 12 |