QuickSpecs

HP ProLiant SL160z Generation 6 (G6)

Standard Features

Industry Standard

ACPI V2.0 Compliant

Compliance

PCI 2.2 Compliant

 

PXE Support

 

WOL Support

 

Microsoft® Logo certifications

 

IPMI 2.0

 

DCMI 1.0

 

SMASH CLP compliant

 

 

 

Security

Power-on password

 

Setup password

 

Diskette boot control

 

Secure Sockets Layer (SSL)

 

Secure Shell (SSH)

 

 

 

Security - Trusted

The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used

Platform Module

to authenticate the server platform. These artifacts can include passwords, certificates and

 

encryption keys. Windows® BitLocker™ Drive Encryption (BitLocker) is a data protection feature

 

available in Windows Server® 2008. BitLocker leverages the enhanced security capabilities of a

 

Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help protect user

 

data and to ensure that a server running Windows Server 2008 has not been tampered with while

 

the system was offline.

 

NOTE: For more information about TPM, including a white paper, go to:

 

http://www.hp.com/go/TPM

 

NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment.

 

NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or

 

losing the key could result in data loss.

 

 

 

Server Power Cords

One 6' Highline (IEC-IEC) power cord ships standard

 

NOTE: HP ProLiant DL servers no longer ship standard with NEMA power cords (163719-002)

 

that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are

 

primarily connected to PDU's in data center racks so they now ship standard with only a PDU

 

power cord (416151-B21). If a user wishes to power a ProLiant DL server using a 110V receptacle

 

(NEMA-15), the NEMA power cord (227099-001) must be ordered separately.

 

If customers require a local power cord, they can check the power cord matrix for the appropriate

 

cord. Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix.

 

 

 

UPS and PDU Power

Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page.

Cord Matrix

Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions,

 

requirements, and specifications for UPS and PDU units. Please see the following link:

 

www.hp.com/products/powercords.

 

 

 

DA - 13385 Worldwide QuickSpecs — Version 1 — 6.15.2009

Page 8

Page 8
Image 8
HP SL160Z Industry Standard, Compliance, Security Trusted, Platform Module, Server Power Cords, UPS and PDU Power