QuickSpecs

HP ProLiant SL160z Generation 6 (G6)

Technical Specifications

System Unit

Dimensions (H x W x D) 3.46 x 17.64 x 28.1 in (8.79 x 44.80 x 71.37 cm)

 

(with bezel)

 

 

 

Weight

Maximum

53.7 lb (24.35 kg)

 

(approximate)

(all hard drives, power

 

 

 

supplies, and processors

 

 

 

installed)

 

 

Input Requirements

Rated Line Voltage

90 to 132 VAC

 

(per power supply)

 

180 to 264 VAC

 

 

Rated Input Current

5. 8 Amps (at 100 VAC) to 2.9 Amps (at 200

 

 

 

VAC)

 

 

Rated Input Frequency

47 to 63 Hz

 

BTU Rating

Rated Input Power

570W (at 100 VAC)

 

 

 

565W (at 200 VAC)

 

 

Maximum

-500W 1940 BTU / hr (at 100 VAC), 1920

 

 

 

BTU/hr (at 200 VAC)

 

 

 

460W - 1773 BTU / hr (at 120 VAC), 1715 (at

 

 

 

240 VAC)

 

 

 

750W - 2892 BTU / hr (at 120 VAC), 2797 (at

 

 

 

240 VAC)

 

Power Specifications

To review typical system power ratings use the HP Power Advisor which

 

 

is available via the online tool located at URL: www.hp.com/go/proliant-

 

 

energy-efficient

 

 

Power Supply Output

Rated Steady-State

500 Watts (at 100 VAC),

 

(per power supply)

Power

500 Watts (at 200 VAC)

 

 

Maximum Peak Power

500Watts (at 100 VAC),

 

 

(See Power

500 Watts (at 200 VAC)

 

 

Specifications Tables)

 

 

System Inlet

Operating

10° to 35°C (50° to 95°F) at sea level with an

 

Temperature

 

altitude derating of 1.0°C per every 305 m

 

 

 

(1.8°F per every 1000 ft) above sea level to a

 

 

 

maximum of 3050 m (10,000 ft), no direct

 

 

 

sustained sunlight. Maximum rate of change

 

 

 

is 10°C/hr (18°F/hr). The upper limit may be

 

 

 

limited by the type and number of options

 

 

 

installed.

 

 

 

System performance may be reduced if

 

 

 

operating with a fan fault or above 30°C

 

 

 

(86°F).

 

 

Non-operating

-30° to 60°C (-22° to 140°F). Maximum rate of

 

 

 

change is 20°C/hr (36°F/hr).

 

Relative Humidity

Operating

10 to 90% relative humidity (Rh), 28°C

 

(non-condensing)

 

(82.4°F) maximum wet bulb temperature, non-

 

 

 

condensing.

 

 

Non-operating

-30° to 60°C (-22° to 140°F). Maximum rate of

 

 

 

change is 20°C/hr (36°F/hr).

 

Altitude

Operating

3050 m (10,000 ft). This value may be limited

 

 

 

by the type and number of options installed.

 

 

 

Maximum allowable altitude change rate is

 

 

 

457 m/min (1500 ft/min).

 

 

Non-operating

9144 m (30,000 ft). Maximum allowable

 

 

 

altitude change rate is 457 m/min (1500

 

 

 

ft/min).

 

Acoustic Noise

Listed are the declared A-Weighted sound power levels (LWAd) and

DA - 13385 Worldwide QuickSpecs — Version 1 — 6.15.2009