Image 5

QuickSpecs

HP Smart Array P411 Controller

Standard Features

Capacity

Given the increasing need for high performance and rapid capacity expansion, the SA-P411 offers:

Up to 48TB of external storage per controller with 1 x HP MSA2040 SAN Storage and 12 x 4TB LFF

SAS hard drives

Up to 24TB of external storage per controller with 1 x HP MSA2040 SAN Storage and 24 x 1TB SFF

SAS hard drives

Up to 384TB of external storage per controller with 8 x HP D2600 Disk Enclosure and 96 x 4TB 3.5"

SAS or SATA hard drives

Up to 240TB of external storage per controller with 8 x HP D2700 Disk Enclosures and 200 x 1.2TB

SFF SAS hard drives

Up to 200 TB of external storage per controller with 8 x HP D2700 Disk Enclosures and 200 x 1TB

SFF SATA hard drives

NOTE: Please check the website of the supported Disk Storage System to get the most recent information on maximum capacity.

Availability

Provides increased server uptime by providing advanced storage functionality:

Online RAID Level Migration (between any RAID level/with BBWC or FBWC)

Online Capacity Expansion (with BBWC or FBWC)

Online Advanced Capacity Expansion (with Smart Array Advanced Pack)

Logical Drive Capacity Extension (with BBWC or FBWC)

Global Online Spare

Pre-Failure Warranty

Fault Prevention

The following features offer detection of possible failures before they occur, allowing preventive action to

 

be taken:

 

S.M.A.R.T. (Self Monitoring Analysis and Reporting Technology) was first developed by HP which

 

detects possible hard disk failure before it occurs, allowing replacement of the component before

 

failure occurs.

 

Drive Parameter Tracking monitors drive operational parameters, predicting failure and notifying

 

the administrator.

 

Dynamic Sector Repairing continually performs background surface scans on the hard disk drives

 

during inactive periods and automatically remaps bad sectors, ensuring data integrity.

 

Smart Array Cache Tracking monitors integrity of controller cache, allowing pre-failure preventative

 

maintenance.

 

Environment Tracking for External Storage System: Monitors fan speed and cabinet temperature of

 

Modular Smart Array Enclosures and HP Disk Enclosures.

 

 