tmpfs

190636

0

190636

0%

/dev/shm

/dev/mapper/DP_Grp-DP_Vol

2780848

5768

2775080

1%

/FileShare

4.Run the opt/omni/sbin/install/omniforsg.ksh script on the primary node: $/opt/omni/sbin/install/omniforsg.ksh –primary

RUNNING: /opt/omni/sbin/omnidbutil -change_cell_name –force DONE!

RUNNING: /opt/omni/sbin/omnisv.sh –stop

RUNNING: mkdir -p / FileShare /etc_opt_omni_server

RUNNING: cp -Rp /etc/opt/omni/server/. / FileShare /etc_opt_omni_server

RUNNING: mv /etc/opt/omni/server /etc/opt/omni/server.save

RUNNING: ln -s / FileShare/etc_opt_omni_server /etc/opt/omni/server

RUNNING: cp -Rp /var/opt/omni/server/. / FileShare /var_opt_omni_server

RUNNING: mv /var/opt/omni/server /var/opt/omni/server.save

RUNNING: ln -s / FileShare /var_opt_omni_server /var/opt/omni/server

cat: /etc/opt/omni/server/cell/installation_servers: No such file

RUNNING: echo dpi00180.ipr.com > /etc/opt/omni/client/cell_server

RUNNING: /opt/omni/sbin/omnisv.sh –start

HP Data Protector services successfully started.

RUNNING: /opt/omni/sbin/omnidbutil -change_cell_name –force DONE!

RUNNING: /opt/omni/sbin/omnisv.sh –stop

HP Data Protector services successfully stopped.

Installing and integrating on the secondary node

1.Install Data Protector locally on the secondary node, by repeating step 1 of the primary node installation.

2.Perform the failover of the shared disk on the secondary node, and run the following script: $ opt/omni/sbin/install/omniforsg.ksh -secondary /FileShare

RUNNING: /opt/omni/sbin/omnisv.sh –stop

HP Data Protector services successfully stopped.

RUNNING: echo >> /FileShare/etc_opt_omni_server/cell/cell_info

RUNNING: cat /etc/opt/omni/server/cell/cell_info >> / FileShare/etc_opt_omni_server/cell/cell_info

RUNNING: mv /etc/opt/omni/server /etc/opt/omni/server.save

RUNNING: mv /var/opt/omni/server /var/opt/omni/server.save

RUNNING: ln -s / FileShare /etc_opt_omni_server /etc/opt/omni/server

RUNNING: ln -s / FileShare /var_opt_omni_server /var/opt/omni/server

RUNNING: echo dpi00180.ipr.com > /etc/opt/omni/client/cell_server

RUNNING: echo CELL SERVER IS: ‘cat /etc/opt/omni/client/cell_server’

CELL SERVER IS: dpi00180.ipr.com

3.Check that the Data Protector services can be stopped and started without error by using the following commands:

$/opt/omni/sbin/omnisv start

HP Data Protector services successfully started. $/opt/omni/sbin/omnisv stop

HP Data Protector services successfully stopped.

Also check that you can open the Cell Manager GUI: $/opt/omni/sbin/omnisv start

5