HP Virtual Connect Firmware manual Prerequisites

Models: Virtual Connect Firmware

1 18
Download 18 pages 28.91 Kb
Page 9
Image 9

The VCM GUI does not redirect to the correct IP after a VC failover.

Workaround

The next failover succeeds without any issues. Refreshing the browser or closing and opening a new session redirects the browser to the correct IP address.

Issue

Errors are received when changing an FCoE network to a different module in a VCEM environment.

Workaround

The customer must revert the changes, and then complete or cancel the domain maintenance mode. If the uplink must be changed to a different module, the customer can delete the existing network, and then re-create the network with the same name, but use different uplinks.

Issue

Under certain circumstances, the checkpoint status icon in the GUI persists for a long time and is not cleared. The CLI also shows a "Checkpoint Status: Invalid" status in the show domain command output. This condition occurs periodically after a VCSU firmware upgrade of the VC module firmware.

Workaround

To resolve this issue, reset VCM on the primary module or reset the primary module using the OA.

Prerequisites

VC SR-IOV prerequisites:

o Supports the following adapters:

HP Flex-10 10Gb 2-port 530FLB Adapter

HP FlexFabric 10Gb 2-port 534FLB Adapter

HP Flex-10 10Gb 2-port 530M Adapter

HP FlexFabric 10Gb 2-port 534M Adapter

HP NC552m Flex-10 Adapter

HP NC553m 10Gb 2-P FlexFabric Converged Network Adapter

HP FlexFabric 10Gb 2-port 554M Adapter

HP Flex-10 10Gb 2-port 552M Adapter

HP FlexFabric 10Gb 2-port 554FLB Adapter

HP FlexFabric 20Gb 2-port 630FLB Adapter

HP FlexFabric 20Gb 2-port 630M Adapter

oSupports the following operating systems:

Windows 2012 (64-bit)

VMware ESXi 5.1 U2, 5.5 (64-bit)

RHEL 5.9 and 5.10 (64-bit with KVM)

RHEL 6.4 and 6.5 (64-bit with KVM)

Prerequisites 9

Page 9
Image 9
HP Virtual Connect Firmware manual Prerequisites