Table 6-1  Troubleshooting (Continued)
Condition  | Possible cause  | Checks  | Action  | 
  | 
  | 
  | 
  | 
Engine does not crank  | Remote switch faulty  | Check switch and  | Repair circuits  | 
with Remote Start  | Main Logic Board  | switch circuits  | Replace switch  | 
  | 
  | 
  | |
Cranks when water  | faulty  | Check Main Logic  | Replace Main logic  | 
pressure decreases  | 
  | Board  | Board  | 
  | 
  | 
  | 
  | 
Engine does not start  | Power Sense Board or  | Check Power Sense  | Replace Power Sense  | 
after AC power loss  | Main Logic Board  | Board  | Board  | 
  | faulty  | 
  | 
  | 
  | 
  | Check Main Logic  | Replace Main Logic  | 
  | 
  | Board  | |
  | 
  | Board  | |
  | 
  | 
  | |
  | 
  | 
  | 
  | 
Engine does not stop  | Another start condition  | Check controller start  | 
  | 
with optional AUTO  | present  | conditions  | 
  | 
STOP | Main Logic Board  | Check Main Logic  | Replace Main Logic  | 
  | |||
  | faulty  | Board  | Board  | 
  | 
  | 
  | 
  | 
Note
The above troubleshooting guide does not represent all possible conditions or problems. If the above information can not resolve a problem, consult the factory or a local representative for further assistance.