Hubbell MSH Recovery Ratings And Amperage At Selected KW, Electrical, Marine Products Division

Models: MH MSH

1 12
Download 12 pages 51.15 Kb
Page 6
Image 6
Recovery Ratings And Amperage At Selected KW

Marine Products Division

Recovery Ratings And Amperage At Selected KW

KW

INPUT

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

110

120

125

150

175

200

225

250

275

300

325

350

375

400

450

500

1000

1200

1400

1600

BTU/HR

 

Gallons Per Hour (GPH) Heated At

 

 

Amperage Rating At Various Voltages

 

 

Various Temperature Rises

 

 

 

RATING

60 °F Δ

80 °F Δ

100 °F Δ

120 °F Δ
140 °F Δ

208V 3F

 

240V 3F

380V 3F

440V 3F

480V 3F

 

 

51,195

103

77

62

51

44

42

 

36

23

21

 

18

68,260

137

103

82

68

59

56

 

48

30

28

 

24

85,325

171

128

103

85

73

69

 

60

38

35

 

30

102,390

205

154

123

103

88

83

 

72

46

42

 

36

119,455

239

179

144

120

103

97

 

84

53

49

 

42

136,520

273

205

164

137

117

111

 

96

61

56

 

48

153,585

308

231

185

154

132

125

 

108

68

63

 

54

170,650

342

256

205

171

146

139

 

120

76

70

 

60

187,715

376

282

226

188

161

153

 

132

84

77

 

66

204,780

410

308

246

205

176

167

 

145

91

84

 

72

221,845

444

333

267

222

190

181

 

157

99

91

 

78

238,910

478

359

287

239

205

195

 

169

106

97

 

84

255,975

513

384

308

256

220

208

 

181

114

104

 

90

273,040

547

410

328

273

234

222

 

193

122

111

 

96

290,105

581

436

349

290

249

236

 

205

129

118

 

102

307,170

615

461

369

308

264

250

 

217

137

125

 

108

324,235

649

487

390

325

278

264

 

229

145

132

 

114

341,300

683

513

410

342

293

278

 

241

152

139

 

120

375,430

752

564

451

376

322

306

 

265

167

153

 

132

409,560

820

615

492

410

351

333

 

289

183

167

 

145

426,625

854

641

513

427

366

347

 

301

190

174

 

151

511,950

1025

769

615

513

439

417

 

361

228

209

 

181

597,275

1196

897

718

598

513

486

 

421

266

244

 

211

682,600

1367

1025

820

683

586

556

 

482

304

279

 

241

767,925

1538

1153

923

769

659

625

 

542

342

313

 

271

853,250

1708

1281

1025

854

732

695

 

602

380

348

 

301

938,575

1879

1409

1128

940

805

764

 

662

418

383

 

331

1,023,900

2050

1538

1230

1025

879

834

 

723

456

418

 

361

1,109,225

2221

1666

1333

1110

952

903

 

783

494

453

 

391

1,194,550

2392

1794

1435

1196

1025

973

 

843

532

487

 

421

1,279,875

2563

1922

1538

1281

1098

1042

 

903

570

522

 

452

1,365,200

2733

2050

1640

1367

1171

1112

 

963

608

557

 

482

1,535,850

3075

2306

1845

1538

1318

1251

 

1084

685

627

 

542

1,706,500

3417

2563

2050

1708

1464

1390

 

1204

761

696

 

602

3,412,000

6833

5125

4100

3417

2929

2779

 

2408

1521

1393

 

1204

4,094,400

8200

6150

4920

4100

3514

3335

 

2890

1825

1671

 

1445

4,776,800

9567

7175

5740

4783

4100

3891

 

3372

2130

1950

 

1686

5,459,200

10933

8200

6560

5467

4686

4446

 

3854

2434

2229

 

1927

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes: The KW selections above are shown for convenience. A full selection of KW ratings from 1 to 1600 KW is available by entering the desired KW into the model number. For alternate voltages including 415, 575 and 600 volt, please consult factory.

Electrical

KW  x  1000  ÷  1.73  =  Amps 3 Φ Volts

KW  x  1000  =  Amps 1 Φ Volts

6

Example: 150 KW at 480V 3F

150  x  1000  ÷  1.73  =  180 Total Amp Draw 480

180 ÷ 48 Amps max circuit rating = 3.75 Round up the number of circuits to 4

Note: Each branch circuit is rated at a maximum of 48 Amps and each circuit is typically operated as an independent temperature step.

Page 6
Image 6
Hubbell MSH Recovery Ratings And Amperage At Selected KW, Electrical, Marine Products Division, KW x 1000 = Amps 1 Φ Volts