![Model MSH & MH](/images/new-backgrounds/30349/303495x1.webp)
Model MSH & MH
Shipboard Electric
Water Heater
|
|
|
|
|
|
|
|
| Mode MSH/MH |
|
| Model MSH/MH |
| ||
| Standard Equipment |
|
| Optional Equipment |
| ||
Vessel Construction |
| Vessel | |||||
1. | All welded carbon steel vessel designed and built in |
| 1A. Alternate protective lining: | ||||
|
| strict accordance with the ASME Code Section IV and |
|
| Phenolic epoxy resin. | ||
|
| stamped, certified, and registered with the National Board |
| 1B. Alternate vessel construction: | |||
|
| of Boiler and Pressure Vessel Inspectors. |
| ||||
2. | All internal tank surfaces are lined with a minimum of 5/8" |
|
| Stainless Steel (Please specify Type: 304, 316 or 316L) | |||
|
| 90/10 | |||||
|
| thick Hydrastone cement for superior protection and tank |
| 1C. Alternate working pressure: | |||
|
| longevity. |
| ||||
3. | Designed for 100psi working pressure and hydrostatically |
|
| Please specify | |||
|
|
|
| ||||
|
| tested at 150psi (1 1/2 times the WP). |
|
|
|
| |
| General |
| General | ||||
1. | Heavy duty 2" thick fiberglass blanket insulation covers |
| |||||
|
| the pressure vessel for maximum operating efficiency and |
| 1. | Skid mounting on heavy duty all welded I Beam | ||
2. | minimal standby heat loss. |
| 2. | Type 304 stainless steel protective jacket, | |||
Heavy gauge galvanized steel protective jacket holds |
|
| please specify if painted. | ||||
|
| insulation in place and protected to ensure highly efficient |
| 3. | Dual energy package provides operational flexibility | ||
|
| operation. |
| ||||
3. | Integrally welded bulkhead attachment points. |
|
| for electric and (steam or boiler water) power. | |||
|
| See page 8 for details. | |||||
4. | Entire vessel is supported on heavy duty integrally welded |
|
|
|
| ||
5. | steel supports for sturdy deck mounting. |
|
|
|
| ||
Full five (5) year Non |
|
|
|
| |||
6. | year electrical component warranty. |
|
|
|
| ||
Bronze ASME/CSA rated combination temperature and |
|
|
|
| |||
|
| pressure safety relief valve set at the vessel working |
|
|
|
| |
7. | pressure and 210ºF. |
|
|
|
| ||
ABS approved and in conformance with USCG |
|
|
|
| |||
|
| regulations. |
|
|
|
| |
|
|
| |||||
| Electrical Operating Controls |
| Electrical |
| |||
1. | All electrical operating controls are factory sized, |
| 1. | NEMA 4 watertight enclosure for outdoor/wet locations. | |||
|
| selected, wired, tested, and mounted in a NEMA 1 |
| 2. | Explosion resistant enclosure for hazardous locations. | ||
|
| enclosure to ensure safe and reliable operation. |
| ||||
2. | A power distribution block is supplied for single point |
|
| Please specify class, division, and group. | |||
| 3. | ||||||
|
| electrical installation. |
| ||||
3. | Power fuses rated at a maximum of 60 Amps protect |
|
| ||||
| 4. | Alternate element sheath material (Please specify: | |||||
|
| each heating element branch circuit per NEC and UL |
| ||||
|
| requirements. Each branch circuit has a maximum rating |
| 5. | Incoloy, Stainless Steel, other). | ||
4. | of 48 Amps. |
| Specialized heating element construction including: | ||||
Heavy duty definite purpose magnetic contactor with |
|
| Special watt density rating, passivation, electropolishing, | ||||
|
| integrally mounted power fuse block assembly switches |
|
| hermetic seals or any other feature required to meet the | ||
5. | power on/off to each branch circuit. |
| 6. | needs of your application. | |||
Heavy duty removable flange type immersion heating |
| Factory installed low water cut out device to disengage | |||||
6. | element provides long service life. |
|
| electrically the heating element(s) in the event of | |||
Fully adjustable thermostat maintains accurate water |
| 7. | insufficient water in the tank. | ||||
|
| temperature and is sized by the factory to control the |
| Dial thermometer and pressure gauge factory installed in | |||
7. | appropriate number of heating element circuits. |
|
| the tank. | |||
A generously sized transformer provides fused 120V to |
| 8. | |||||
8. | the control circuit |
|
| continuously circulate water within the tank and thereby | |||
A fully adjustable |
|
| reduce stratification. All bronze circulator pump is rated | ||||
|
| manual reset interrupts power to the control circuit in the |
| 9. | 1/12 HP, 120V, 1 Ph. | ||
9. | event of |
| Status indicating lamp(s). | ||||
Safety door interlock mechanism interrupts power to the |
| 10. | Audible alarm system. | ||||
10. | control circuit upon opening the electrical control panel. |
| 11. | Digital display electronic temperature controller. Please | |||
Louvers in the control panel allow for cooling of the |
| ||||||
|
| specify with or without RS485 communication port for | |||||
|
| electrical components to ensure maximum electrical |
|
| remote operation of the temperature controller. | ||
|
| component longevity (when required). |
|
| |||
|
|
| 12. | Additional ground connections | |||
|
|
|
|
| |||
|
|
|
|
| |||
|
|
|
|
|
| 3 |