41644_model44360_web.pmd
10
INSTALLATION | 10 |
If the code letter on your existing thermostat is
RH, R, VR or 4 24 Volt
then mark the wire | and connect to thermostat |
with label shown | terminal shown |
| RH |
| x |
H |
|
R |
|
RC, VC
24 Volt Cool
G or F
Fan
Y, C or M
Air Conditioning Compressor - or -
O
Reversing Valve operating in Cool mode. (Single Stage Heat Pumps ONLY.)
W or H Heating - or -
B
Reversing Valve operating in Heat mode. (Single Stage Heat Pumps ONLY.)
Y1
Heat Pump compressor
(Single Stage Heat Pumps ONLY.)


RC
G
/O Y
W/B
Y1
RC
x
G
x
Y/O
x
W/B
x
Y1
x
NOTE: Do not connect a “Common” wire (sometimes labeled “C”) to any terminal on this thermostat. Tape up the wire and do not use. This wire provides electricity to
11
Mount Wallplate and Thermostat | 11 |
■Remove the wallplate from your thermostat by pressing the release tab on the bottom of the thermostat. (See Figure 2.)
■Position wallplate on wall and pull existing wires through large opening. Then level for appearance. Mark holes for plastic anchors provided if your existing holes do not line up with those on the Hunter wallplate.
■Drill holes with 3/16” bit and gently tap anchors into the holes until flush with wall.
■Reposition wallplate to wall, pulling wires through large opening. Insert mounting screws provided into wall anchor and tighten. (See Figure 3.)
Y1
W/B
| Rh | Y/O |
Rc |
| |
|
| |
G |
|
|
Figure 2 | Figure 3 |
If your thermostat has one wire marked R or RH
Otherwise, if you have separate RH and RC wires