4 •Wiring the Fan

4 •Wiring the Fan

All wiring must be in accordance with national and local electrical codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified electrician.

Wall switches are not included. Select an acceptable general-use switch in accordance with national and local electrical codes.

4-1. Before attempting installation, make sure the power is still off.

4-2. To connect the wires, hold the bare metal leads together and place a wire connector over them, then twist clockwise until tight. For all these connections use the wire connectors provided.

4-3. Connect the bare or green ground wire (grounding) from the ceiling to the green ground wire (grounding) from the ceiling plate and the green ground wire from the fan.

4-4. Connect the white wire (grounded) from the ceiling to the white wire (grounded) from the fan.

4-5. Connect the remaining wires as follows:

Dual Switch Wiring:

The black wire (ungrounded) from the ceiling to the black wire (ungrounded) from the fan

The black/white wire (ungrounded) from the fan to the wire (ungrounded) for the wall switch

Single Switch Wiring:

The black wire (ungrounded) from the ceiling to the black (ungrounded) and the black/white wire (ungrounded) from the fan

Dual Switch Wiring: CAUTION: Be sure no bare wire or wire strands are visible after making connections.

4-6. Turn the wire connectors upward and push them carefully back through the ceiling plate into the outlet box.

4-7. Spread the wires apart, with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box.

Wire

Connector

7

45043-01 • 10/19/09 • Hunter Fan Company

Page 7
Image 7
Hunter Fan 45043-01 installation manual Wiring the Fan, Dual Switch Wiring, Single Switch Wiring

FAQ

What are the national and local electrical codes that should be followed for wiring the Hunter Fan model 45043-01?

All wiring must be in accordance with national and local electrical codes and ANSI/NFPA 70. If you are unfamiliar with wiring, it is recommended to use a qualified electrician.

Are wall switches included with the Hunter Fan model 45043-01?

No. Wall switches are not included. Select an acceptable general-use switch in accordance with national and local electrical codes.

How should the wires be connected for dual switch wiring?

The black wire ungrounded from the ceiling should be connected to the black wire ungrounded from the fan. The black/white wire ungrounded from the fan should be connected to the wire ungrounded for the wall switch.