The compressor should be checked often for any visible problems and the following maintenance procedures should be performed each time the compressor is used.

1.Pull ring on safety valve and allow it to snap back to normal position.

! WARNING

Safety valve must

be replaced if it

cannot be actuated or it leaks air after ring is released.

2.Place unit in the horizontal position as shown in Figure 8. With compressor shut off and pressure released: Drain moisture from tank

by opening drain cock underneath tank.

3.Turn power OFF and clean dust and dirt from pump cover, tank and air lines.

IMPORTANT: Unit should be located as far from spraying area as hose will allow to prevent over-spray from clogging filter.

LUBRICATION

This is an oilless type compressor requiring no lubrication.

STORAGE

1.When not in use, hose and compres- sor should be stored in a cool dry place.

2.Tank should be drained of moisture.

3.Hose should be disconnected and hung open ends down, to allow any moisture to drain.