Husky FP2205 operating instructions Oilless Compressors Troubleshooting Chart

Models: FP2205

1 24
Download 24 pages 52.57 Kb
Page 6
Image 6

Oilless Compressors

Troubleshooting Chart

SymptomPossible Cause(s)Corrective Action

 

Compressor will not run

1. No electrical power

1.

Plugged in? Check fuse/breaker or motor overload

 

 

2.

Breaker open

2.

Reset, determine cause of problem

 

 

3.

Pressure switch bad

3.

Replace

 

 

 

4.

Check valve defective

4.

Remove and replace check valve

 

 

 

 

! DANGER

Do not disassemble check valve

 

 

 

 

with air in tank; bleed tank

 

 

 

 

 

 

Motor hums but cannot

1. Poor contacts, line voltage incorrect

1.

Check connections, check with voltmeter

 

run or runs slowly

2. Shorted or open motor winding

2.

Replace motor

 

 

 

3.

Defective check valve or unloader

3.

Replace or repair

 

 

 

 

 

! DANGER

Do not disassemble check valve

 

 

 

 

with air in tank; bleed tank

 

 

 

 

 

 

 

Fuses blow/circuit

1. Incorrect size fuse, circuit overloaded

breaker trips repeatedly

 

! CAUTION

2. Defective check valve or unloader

Never use an extension cord with this product

1.Check for proper fuse, use time-delay fuse. Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit

2.Replace or repair

! DANGER

Do not disassemble check valve

with air in tank; bleed tank

Tank pressure drops when compressor shuts off

1.

Loose connections (fittings, tubing,

1.

Check all connections with soap and water solution

 

etc.)

 

 

and tighten

 

2.

Loose drain cock

2.

Tighten

 

3.

Check valve leaking

3.

Disassemble check valve assembly, clean or replace

 

 

 

 

 

Do not disassemble check valve

 

 

 

! DANGER

 

 

 

with air in tank; bleed tank

 

 

 

 

Air output lower than normal/low discharge pressure

1.

Air leaks in piping (on machine or in

1.

Replace leaking components or tighten as necessary

 

outside system)

 

 

2.

Piston ring broken

2.

Replace

6

Page 6
Image 6
Husky FP2205 operating instructions Oilless Compressors Troubleshooting Chart