Charging the Battery

1.Press 2/6/10 AMP button to begin charging at the 2 amp rate; the unit sounds a beep and displays charging current. The charger starts charging at 2 amp rate automatically if 2/6/10 AMP button is not pressed within 3 minutes after applying AC power.

Charger occasionally sounds a beep and displays “0.0” during self-test or charging stage changes.

2.Pressing the 2/6/10 AMP button again advances charging rate to 6 amps and pressing once more advances charging rate to 10 amps. (Pressing the button again will turn OFF the charger output and the Display will show “000”.) This selection and actual battery charge rate are monitored by the microprocessor and the unit will stop charging if the selected rate is too fast or too slow for battery size or condition.

As the battery nears full charge capacity, the unit’s output will automatically drop to a lower charge rate.

3.The battery charger displays the charge current. To view the battery voltage, press BATTERY VOLTAGE button. The charger will sound a beep and display the the battery voltage. Press BATTERY VOLTAGE again to return to displaying the charge current.

4.The display shows “FUL” when the battery is fully charged.

5.Disconnect the AC power cord first, then the NEGATIVE clamp, and finally the POSITIVE clamp.

Automatic Float Charging

Automatic Float Charging is ideal for maintaining a fully charged battery.

1.Keep the AC power and battery connected after battery is fully charged.

2.The charger monitors the battery and tops it off as needed.

3.The display shows “FLO” when topping off the battery and returns to “FUL” when completed.

4.To view battery voltage, press the Battery Voltage button.

Note: Charging can be terminated by pressing the 2/6/10 AMP button at any time when the unit is charging.

After AC power interruption, charging restarts at 2 amp rate automatically.

WARNING

If battery size is not known, charge at the 2 amp rate. DO NOT overcharge batteries.

Alternator Check

Part 1

No Load (Turn OFF all vehicle’s accessories): The battery must be fully charged before testing the alternator. Run the engine long enough to achieve normal idle speed and verify there is a no-load voltage.

1.Press Alternator Check to start the check.

2.Alternator Good LED will light to indicate the alternator is good, or the FAULT LED will light to indicate the alternator may need service.

3.Press Alternator Check again to stop the test.

Part 2

Under Load (Accessories ON): Next, load the alternator by turning on as many accessories as possible (except for A/C and DEFROST)

1.Press Alternator Check to start the check.

2.Alternator Good LED will light to indicate the alternator is good, or the FAULT LED will light to indicate the alternator may need service.

3.Press Alternator Check again to stop the test.

If the first alternator check indicates a good alternator and the second indicates the alternator may need service, the problem could stem from: loose fan belts, an intermittent diode failure or possibly bad connections between the battery and alternator and/or ground.

NOTES BATTERY VOLTAGE button is disabled in Alternator Check mode.

The FAULT LED may light because someone has added a number of accessory loads on the charging system, thereby increasing current demand from the alternator. MAKE SURE THAT THE ALTERNATOR IS RATED TO SUPPORT THE APPLICATION.

This check may not be accurate for every make, manufacturer and model of vehicle.

Check only 12 volt systems.

APPROXIMATE CHARGING TIMES

The 2/6/10 Amp 12 Volt Smart Battery Charger will automatically adjust the charge rate as the battery becomes charged, and stop when the battery is fully charged. Deep cycle batteries may require longer charging time.

For estimates of the time it takes to charge a battery, refer to the following table.

Percent of charge

 

 

 

 

 

 

 

in battery

75%

50%

25%

0%

at 2 amp rate

7

HRS

14

HRS

NR*

NR*

at 6 amp rate

2.5

HRS

4.7

HRS

7

HRS

9.2 HRS

at 10 amp rate

1.4

HRS

2.8

HRS

4.2

HRS

5.5 HRS

*NR = Not recommended at 2 amps — use a higher charge rate.

The times shown in the table above are approximate and refer to a 50 Ah automotive battery. For example, a 50 Ah (12 volt) battery is discharged (50%). How long should it be charged at the 10 amp rate? See the chart above under “50%” and “at 10 amp rate.”

In most cases, battery charging times will vary depending on the size, age and condition of the battery. Smaller batteries should be charged at a lower rate (2 amps) and an extra hour added to charge time.

CARE AND MAINTENANCE

With proper care and minimal maintenance, the 2/6/10 Amp 12 Volt Smart Battery Charger will provide years of dependable service. For maximum performance, manufacturer recommends:

After each use, clean the battery charger clamps — be sure to remove any battery fluid that will cause corrosion of the copper clamps.

Clean the outside case of the charger with a soft cloth and, if necessary, mild soap solution.

Do not allow liquid to enter the charger. Do not operate when charger is wet.

Keep the charger cords loosely coiled during storage to prevent damage to the cords.

4

5

Page 5
Image 5
Husky HSK1084HD Approximate Charging Times, Care and Maintenance, Charging the Battery, Automatic Float Charging